To quantify the effect of two distinct foot orthotic designs on in vivo multisegment foot and leg motion; in particular, the first metatarsal and first metatarsophalangeal (MTP) joint during gait. A 23-year-old man had an excessively pronated foot structure as measured during a clinical orthopedic examination. The Optotrak Motion Analysis System was used to collect three-dimensional position and orientation data from four modeled rigid body segments (hallux, first metatarsal, calcaneus, and tibia) during the stance phase of walking. The subject walked at a self-selected comfortable walking speed, and a minimum of five trials were collected under three different test conditions: no orthosis, semirigid orthosis with a varus post, and a semirigid orthosis with a varus post and a large medial flange. Data were normalized to the stance period, and descriptive statistics were calculated for dependent variables. Both orthotic interventions equally modified first MTP joint motion when compared with the no orthotic condition. First MTP joint dorsiflexion was decreased (>2 SD) with the orthosis during terminal stance phase. This decrease was associated with a concomitant increase in first metatarsal plantar flexion. A custom-made semirigid orthosis posted medially and made from a neutral position off-weight-bearing plaster cast can alter motion in the forefoot during the propulsive period by increasing first metatarsal plantar flexion and decreasing excessive first MTP joint dorsiflexion.Keywords
This publication has 18 references indexed in Scilit:
- The Effect of Forefoot and Arch Posting Orthotic Designs on First Metatarsophalangeal Joint Kinematics During GaitJournal of Orthopaedic & Sports Physical Therapy, 2004
- Effects of foot orthoses on skeletal motion during runningClinical Biomechanics, 2000
- Nonoperative and Operative Intervention for Hallux RigidusJournal of Orthopaedic & Sports Physical Therapy, 1999
- Reliability and validity of first metatarsophalangeal joint orientation measured with an electromagnetic tracking deviceClinical Biomechanics, 1999
- The Frontal Plane Relationship of the Forefoot to the Rearfoot in an Asymptomatic PopulationJournal of Orthopaedic & Sports Physical Therapy, 1994
- Reliability of Open and Closed Kinetic Chain Subtalar Joint Neutral Positions and Navicular Drop TestJournal of Orthopaedic & Sports Physical Therapy, 1993
- Role of soft tissue structures as an etiology of hallux limitusJournal of the American Podiatric Medical Association, 1993
- Closed Versus Open Kinematic Chain Measurements of Subtalar Joint Eversion: Implications for Clinical PracticeJournal of Orthopaedic & Sports Physical Therapy, 1988
- Biomechanical Analysis of Foot Function during Gait and Clinical ApplicationsClinical Orthopaedics and Related Research, 1983
- Foot orthotic devices to modify selected aspects of lower extremity mechanicsThe American Journal of Sports Medicine, 1979