Force-Feedback Surgical Teleoperator: Controller Design and Palpation Experiments
- 1 March 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23247347,p. 465-471
Abstract
In this paper, we develop and test a 6-degree-of-freedom surgical teleoperator that has four possible modes of operation: (1) direct force feedback, (2) graphical force feedback, (3) direct and graphical force feedback together, and (4) no force feedback. In all cases, visual feedback of the: environment is provided via a head-mounted display. A position-position controller with local dynamic compensators provides the direct force feedback. The graphical force feedback is overlaid on the environment image, and displays a bar whose height and color is related to the environment force estimated using the current applied to the actuators of the patient-side arm. We evaluate the performance of the teleoperator modes in assisting a user to find the location of stiff objects hidden inside a soft material, similar to a calcified artery hidden in heart tissue and a tumor in the prostate. Seven people used the teleoperator t:o perform palpation in these materials. Results showed that direct force feedback mode minimizes palpation task error for the heart model.Keywords
This publication has 11 references indexed in Scilit:
- Effects of visual force feedback on robot-assisted surgical task performanceThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Friction Compensation for Enhancing Transparency of a Teleoperator With Compliant TransmissionIEEE Transactions on Robotics, 2007
- The Benefit of Force Feedback in Surgery: Examination of Blunt DissectionPRESENCE: Virtual and Augmented Reality, 2007
- Enhancing Transparency of a Position-Exchange Teleoperator2007
- Sensor/Actuator Asymmetries in Telemanipulators: Implications of Partial Force Feedback2006
- Development of actuated and sensor integrated forceps for minimally invasive robotic surgerThe International Journal of Medical Robotics and Computer Assisted Surgery, 2005
- Effect of sensory substitution on suture-manipulation forces for robotic surgical systemsThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Computer-enhanced “robotic” cardiac surgery: Experience in 148 patientsThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Remote palpation technologyIEEE Engineering in Medicine and Biology Magazine, 1995
- A perceptual analysis of stiffnessExperimental Brain Research, 1990