The Effect of the Length and Distribution of Implants for Fixed Prosthetic Reconstructions in the Atrophic Posterior Maxilla: A Finite Element Analysis
Open Access
Abstract
In this study, different prosthetic designs that could be applied instead of advanced surgical techniques in atrophic maxilla were evaluated with finite element analysis. Atrophic posterior maxilla was modeled using computer tomography images and four models were prepared as follows: Model 1 (M1), two implants supporting a three-unit distal cantilever prosthesis; Model 2 (M2), two implants supporting a three-unit conventional fixed partial denture; Model 3 (M3), three implants supporting three connected crowns; and Model 4 (M4), two implants supporting two connected crowns. Implants 4 mm in width and 8 mm or 13 mm in length were used. A linear three-dimensional finite element programme was used for analysis. The maximum principle stress (tensile) and minimum principle stress (compressive) were used to display stress in cortical and cancellous bones. The von Mises criteria were used to evaluate the stress on the implants. M1 was found to be the most risky model. The short dental arch case (M4) revealed the lowest stresses among the models but is not recommended when one more implant can be placed because of the bending forces that could occur at the mesial implant. In M2 and M3, the distal implants were placed bicortically between the crestal and sinus cortical plates, causing a fall of the stresses because of the bicortical stability of these implants.Keywords
Funding Information
- Scientific Research Projects Coordination Unit of Istanbul University (T-751)
This publication has 29 references indexed in Scilit:
- The effect of different occlusal contact situations on peri-implant bone stress – A contact finite element analysis of indirect axial loadingMaterials Science and Engineering: C, 2019
- Short dental implant is considered as a reliable treatment option for patients with atrophic posterior maxillaJournal of Evidence-Based Dental Practice, 2016
- Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysisJournal of Dentistry, 2016
- Maxillary Sinus AugmentationDental Clinics of North America, 2015
- Number and localization of the implants for the fixed prosthetic reconstructions: On the strain in the anterior maxillary regionMedical Engineering & Physics, 2015
- Longevity of dental implants in type IV bone: a systematic reviewInternational Journal of Oral and Maxillofacial Surgery, 2014
- Angled abutments result in increased or decreased stress on surrounding bone of single-unit dental implants: A finite element analysisMedical Engineering & Physics, 2012
- Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the boneJournal of Dentistry, 2002
- A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forcesJournal of Biomechanics, 1988
- Biomechanical considerations in osseointegrated prosthesesThe Journal of Prosthetic Dentistry, 1983