Using Nanosensors for In Situ Monitoring and Measurement of Nitric Oxide and Peroxynitrite in a Single Cell
- 13 September 2014
- book chapter
- Published by Springer Nature
- Vol. 1208, 139-155
Abstract
The cytotoxic peroxynitrite (ONOO−) is an oxidation product of the cytoprotective nitric oxide (NO). Our studies support the hypothesis that the concentration ratio of NO and ONOO−, [NO]/[ONOO−] can be a marker of nitroxidative imbalance, which subsequently correlates well with endothelial dysfunction and dysfunction of the cardiovascular system. Nanosensors, described here, have been used for simultaneous monitoring and measurement of NO and ONOO− release from a single endothelial cell. These nanosensors, with a diameter of 200–300 nm, can be positioned accurately in close proximity of 5–10 μm from the endothelial cell membrane. The response time of the sensors is better than a millisecond and the detection limit is 10−9 M, with a linear concentration response of up to about 2 μM. The application of these sensors for the measurement of the balance and imbalance of [NO]/[ONOO−] in normal and dysfunctional endothelium is demonstrated.Keywords
This publication has 17 references indexed in Scilit:
- Peroxynitrite/Nitric Oxide Balance in Ischemia/Reperfusion Injury‐Nanomedical ApproachElectroanalysis, 2006
- Nebivolol Reduces Nitroxidative Stress and Restores Nitric Oxide Bioavailability in Endothelium of Black AmericansCirculation, 2005
- Measurement of Nitric Oxide in Single Cells and Tissue Using a Porphyrinic MicrosensorCurrent Protocols in Neuroscience, 1999
- Tetrahydrobiopterin alters superoxide and nitric oxide release in prehypertensive rats.Journal of Clinical Investigation, 1998
- The Catalytic Role of Carbon Dioxide in the Decomposition of PeroxynitriteFree Radical Biology and Medicine, 1997
- Shear Stress Induces ATP-Independent Transient Nitric Oxide Release From Vascular Endothelial Cells, Measured Directly With a Porphyrinic MicrosensorCirculation Research, 1995
- Nitric Oxide:Biochemistry, Pathophysiology, and DetectionAmerican Journal of Clinical Pathology, 1993
- Direct Electrochemical Measurement of Nitric Oxide Released from Human PlateletsBiochemical and Biophysical Research Communications, 1993
- Diffusion of Nitric Oxide in the Aorta Wall Monitored in Situ by Porphyrinic MicrosensorsBiochemical and Biophysical Research Communications, 1993
- A novel meso-[2.2]paracyclophanyltriphenylporphyrin; electrochemical oxidation and conductive polymeric film formationJournal of the Chemical Society, Chemical Communications, 1989