Studies on RPC position resolution with different surface resistivity of high voltage provider
Authors:
- 1 October 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 917-918
Abstract
The effect of surface resistivity of high voltage provider on the space dispersion of induced charge of RPC has been studied experimentally. The result of experimental measurement shows that two-Gaussian function can be used to fit the dispersion of induced charge of RPC. The Gaussian function with narrower width is mainly due to the expansion of avalanche charge in the gas gap of RPC and the Gaussian function with larger width is due to the charge dispersion when it passes through the resistive carbon film.Keywords
This publication has 3 references indexed in Scilit:
- Study on the space dispersion of induced charge of resistive plate chamber2008
- Study on the position resolution of resistive plate chamberNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- High-rate, high-position resolution microgap RPCs for X-ray imaging applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003