Assessing fluid responses after coronary surgery: role of mathematical coupling of global end-diastolic volume to cardiac output measured by transpulmonary thermodilution
Authors:
- Rob Bp de WildeRWRob Bp de Wilde
- Paul Cm van Den BergPBPaul Cm van Den Berg
- Jos Rc JansenJJJos Rc Jansen
- Theo Jc FaesTFTheo Jc Faes
- Jos Wr TwiskJTJos Wr Twisk
- AB Johan GroeneveldAGAB Johan Groeneveld
- 1 November 2009
- journal article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 26 (11) , 954-960
Abstract
Mathematical coupling may explain in part why cardiac filling volumes obtained by transpulmonary thermodilution may better predict and monitor responses of cardiac output to fluid loading than pressures obtained by pulmonary artery catheters (PACs). Eleven consecutive patients with hypovolaemia after coronary surgery and a PAC, allowing central venous pressure (CVP) and continuous cardiac index (CCIp) measurements, received a femoral artery catheter for transpulmonary thermodilution measurements of global end-diastolic blood volume index (GEDVI) and cardiac index (CItp). One to five colloid fluid-loading steps of 250 ml were done in each patient (n = 48 total). Fluid responses were predicted and monitored similarly by CItp and CCIp, whereas CItp and CCIp correlated at r = 0.70 (P < 0.001) with a bias of 0.40 l min(-1) m(-2). Changes in volumes (and not in CVP) related to changes in CItp and not in CCIp. Changes in CVP and GEDVI similarly related to changes in CItp, after exclusion of two patients with greatest CItp outliers (as compared to CCIp). Changes in GEDVI correlated better to changes in CItp when derived from the same thermodilution curve than to changes in CItp of unrelated curves and changes in CCIp. After coronary surgery, fluid responses can be similarly assessed by intermittent transpulmonary and continuous pulmonary thermodilution methods, in spite of overestimation of CCIp by CItp. Filling pressures are poor monitors of fluid responses and superiority of GEDVI can be caused, at least in part, by mathematical coupling when cardiac volume and output are derived from the same thermodilution curve.Keywords
This publication has 36 references indexed in Scilit:
- Stroke Volume and Pulse Pressure Variation for Prediction of Fluid Responsiveness in Patients Under oing Off-Pump Coronary Artery Bypass GraftingChest, 2005
- Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiographyBritish Journal of Anaesthesia, 2005
- Prediction of fluid responsiveness in patients during cardiac surgeryBritish Journal of Anaesthesia, 2004
- Intrathoracic blood volume index measured by thermodilution for preload monitoring after cardiac surgeryJournal of Cardiothoracic and Vascular Anesthesia, 2002
- Monitoring intravascular volumes for postoperative volume therapy2002
- Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgeryIntensive Care Medicine, 2002
- Assessment of intrathoracic blood volume as an indicator of cardiac preload: Single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheterJournal of Cardiothoracic and Vascular Anesthesia, 2001
- Relationships between volume and pressure measurements and stroke volume in critically ill patientsCritical Care, 2000
- Assessment of cardiovascular volume status by transoesophageal echocardiography and dye dilution during cardiac surgeryEuropean Journal of Anaesthesiology, 1998
- Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patientsEuropean Journal of Cardio-Thoracic Surgery, 1998