Reproducibility and Screening Capability of Corneal Epithelial Thickness Measurement for Keratoconus Using Anterior Segment Optical Coherence Tomography
Open Access
- 1 June 2025
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 2057-2065
Abstract
Purpose: To investigate the reproducibility of corneal epithelial thickness measurements using anterior segment optical coherence tomography (AS-OCT, CASIA2, TOMEY) and evaluate its potential for the diagnosis of keratoconus. Patients and Methods: This study included patients diagnosed with stage 1– 2 keratoconus (Amsler-Krumeich classification) at the Nagoya Eye Clinic and healthy controls. Corneal epithelial thickness was measured with the CASIA2 AS-OCT. Sixteen patients with keratoconus (16 eyes) and 11 healthy controls (11 eyes) underwent three consecutive measurements to determine the intraclass correlation coefficient (ICC). Measurements were taken for eight corneal sections in 40 keratoconus eyes (mean age: 25.5 ± 8.0 years) and 44 normal eyes (mean age: 24.2 ± 5.1 years). The mean corneal epithelial thickness, the upper-to-lower corneal epithelial thickness ratio, and the standard deviation of thickness across segments were compared between the two groups. Logistic regression analysis was used to evaluate corneal epithelial thickness-related parameters for the diagnosis of keratoconus. The cutoff value was determined using the Youden index derived from the receiver operating characteristic (ROC) curve. Results: The ICC was ≥ 0.95 in all areas for both keratoconus and normal eyes. The superior paracentral corneal epithelium was significantly thicker in the keratoconus eyes, whereas the inferior paracentral area was thinner compared to normal eyes (p< 0.001). The standard deviation of corneal epithelial thickness was significantly higher in keratoconus eyes across all regions. Logistic regression analysis identified the standard deviation of corneal epithelial thickness (2– 5 mm) and the mean thickness ratio (0– 5 mm) as explanatory variables. The area under the ROC curve was 0.955, with sensitivity and specificity of 92.1% and 100%, respectively. Conclusion: Corneal epithelial thickness measurements using the AS-OCT CASIA2 were highly reproducible and showed significant differences between early-stage keratoconus and normal corneas. These findings suggest its potential utility as a screening tool for keratoconus.Keywords
This publication has 30 references indexed in Scilit:
- Role of Corneal Epithelial Measurements in Differentiating Eyes with Stable Keratoconus from Eyes that Are ProgressingOphthalmology Science, 2022
- Keratoconus: An updated reviewContact Lens and Anterior Eye, 2022
- Transepithelial Versus Epithelium-Off Corneal Crosslinking for Progressive Keratoconus: Findings From a Cochrane Systematic ReviewAmerican Journal of Ophthalmology, 2021
- Comparison of angle-to-angle distance using three devices in normal eyesEye, 2019
- Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in KeratoconusAmerican Journal of Ophthalmology, 2019
- Corneal crosslinking for keratoconus in Japanese populations: one year outcomes and a comparison between conventional and accelerated proceduresJapanese Journal of Ophthalmology, 2018
- Keratoconus diagnosis using Corvis ST measured biomechanical parametersJournal of Current Ophthalmology, 2017
- Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomographyJapanese Journal of Ophthalmology, 2014
- Corneal Collagen Cross-linking with Riboflavin and Ultraviolet A Irradiation for KeratoconusOphthalmology, 2013
- Riboflavin/ultraviolet-a–induced collagen crosslinking for the treatment of keratoconusAmerican Journal of Ophthalmology, 2003