Blood spot screening and confirmatory tests for syphilis antibody
Authors:
- 1 September 1992
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 30 (9) , 2353-8
Abstract
We developed a blood spot test for syphilis antibody using enzyme-linked immunosorbent assay (ELISA) technology. Dried blood was eluted by buffered saline or, for a supplementary confirmatory test, by treponemal-antibody test diluent. Eluates were diluted in an absorption buffer (Calypte Biomedical, Berkeley, Calif.) and added to plate wells coated with cardiolipin antigen (ADI Diagnostics, Toronto, Ontario, Canada). The wells were washed and treated sequentially with an immunoglobulin G conjugate, buffer washes, and enzyme substrate. Substrate conversion was measured photometrically, and specimen reactivity was determined by reference to nonreactive controls. The optimum test protocol was established by tests of serum and plasma. The serum ELISA specificity with normal specimens was 98.9%. The sensitivity with sera from patients with undefined syphilis was 97.4%, that with sera from patients with documented primary and secondary disease was 100%, and that with sera from patients with early and late latent disease was 95.7%. The specificity of the spot test with donor blood was 94.2%, and its specificity with newborn blood was 94.9%. The sensitivity with 25 spots spiked with reactive sera was 96%. The seroprevalence rates for parturient women in one hospital were 6.01% according to spot tests of sera from 599 newborns and 6.81% according to Rapid Plasma Reagin tests of 499 maternal serum specimens. Seventy percent of infants born to 50 seropositive women were reactive by either the newborn spot or the Rapid Plasma Reagin serum test. The results show that blood spots may be used in seroprevalence or serodiagnostic studies, especially to identify women who are infected or to identify possible cases of congenital infection. The test provides for studies of children and adults when routine venipuncture and serum handling and storage are problematic.Keywords
This publication has 13 references indexed in Scilit:
- Stability of human immunodeficiency virus type 1 antibodies in whole blood dried on filter paper and stored under various tropical conditions in Kinshasa, ZaireJournal of Clinical Microbiology, 1992
- The relationship of cocaine use to syphilis and human immunodeficiency virus infections among inner city parturient womenAmerican Journal of Obstetrics and Gynecology, 1990
- Risk factors for syphilis: cocaine use and prostitution.American Journal of Public Health, 1990
- False Negative Screening Tests for Syphilis in Pregnant WomenNew England Journal of Medicine, 1990
- CONGENITAL-SYPHILIS - THE UNIVERSITY-OF-MIAMI JACKSON-MEMORIAL-MEDICAL-CENTER EXPERIENCE, 1986-19881989
- A Quality Assurance Program for Human Immunodeficiency Virus Seropositivity Screening of Dried-Blood Spot SpecimensInfection Control, 1989
- Whole Blood Collection on Filter Paper Is an Effective Means of Obtaining Samples for Human Immunodeficiency Virus Antibody AssayAIDS Research and Human Retroviruses, 1988
- Seroprevalence of Human Immunodeficiency Virus among Childbearing WomenThe New England journal of medicine, 1988
- Diagnostic DecisionAnnals of Internal Medicine, 1986
- Screening test for syphilis-specific antibodies added to a screening program for congenital hypothyroidismThe Journal of Pediatrics, 1982