Integrating Retraction Modeling Into an Atlas-Based Framework for Brain Shift Prediction
- 10 July 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (12) , 3494-3504
Abstract
In recent work, an atlas-based statistical model for brain shift prediction, which accounts for uncertainty in the intraoperative environment, has been proposed. Previous work reported in the literature using this technique did not account for local deformation caused by surgical retraction. It is challenging to precisely localize the retractor location prior to surgery and the retractor is often moved in the course of the procedure. This paper proposes a technique that involves computing the retractor-induced brain deformation in the operating room through an active model solve and linearly superposing the solution with the precomputed deformation atlas. As a result, the new method takes advantage of the atlas-based framework's accounting for uncertainties while also incorporating the effects of retraction with minimal intraoperative computing. This new approach was tested using simulation and phantom experiments. The results showed an improvement in average shift correction from 50% (ranging from 14 to 81%) for gravity atlas alone to 80% using the active solve retraction component (ranging from 73 to 85%). This paper presents a novel yet simple way to integrate retraction into the atlas-based brain shift computation framework.Keywords
This publication has 21 references indexed in Scilit:
- On the unimportance of constitutive models in computing brain deformation for image-guided surgeryBiomechanics and Modeling in Mechanobiology, 2008
- An atlas-based method to compensate for brain shift: Preliminary resultsMedical Image Analysis, 2007
- Patient-specific model of brain deformation: Application to medical image registrationJournal of Biomechanics, 2007
- Intraoperative Cortical Surface Characterization using Laser Range Scanning: Preliminary ResultsOperative Neurosurgery, 2006
- Brain Shift Estimation in Image-Guided Neurosurgery Using 3-D UltrasoundIEEE Transactions on Biomedical Engineering, 2005
- An integrated range-sensing, segmentation and registration framework for the characterization of intra-surgical brain deformations in image-guided surgeryComputer Vision and Image Understanding, 2003
- In vivo quantification of retraction deformation modeling for updated image-guidance during neurosurgeryIEEE Transactions on Biomedical Engineering, 2002
- Modeling of Retraction and Resection for Intraoperative Updating of ImagesNeurosurgery, 2001
- Quantification of, Visualization of, and Compensation for Brain Shift Using Intraoperative Magnetic Resonance ImagingNeurosurgery, 2000
- A Review of Brain Retraction and Recommendations for Minimizing Intraoperative Brain InjuryNeurosurgery, 1993