Determination of Labile Iron at Low nmol L−1 Levels in Estuarine and Coastal Waters by Anodic Stripping Voltammetry
- 9 January 2006
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 18 (1) , 35-43
Abstract
A new method is presented for the determination of electrochemically labile iron in estuarine and coastal seawater. The method is based on differential pulse anodic stripping voltammetry (DPASV) at a rotating silver‐alloy disk electrode. The voltammetric parameters include a plating potential of −1.5 V and an activation potential of −5 V for 10s; the seawater is at the original sample pH. The main finding is the presence of a peak for low nmol L−1 levels of iron at −0.55 V ascribed to elemental iron deposited on the bare silver alloy electrode. The peak increased linearly with the iron concentration between −1 using a 900 s plating time. At higher concentrations an additional iron peak appeared at −0.7 V which was also found to increase linearly with the iron concentration but at a higher concentration range from ca. 15 to 90 nmol L−1 using a 300 s plating time. The second peak was ascribed to iron deposited on iron. Additions of chelating agents (EDTA and a siderophore) to seawater caused the iron peak to be masked indicating that this method is suitable for iron speciation as only the electrochemically labile fraction is determined. The detection limit was 0.3 nmol L−1 using a 900 s plating time. The method was used to determine iron in the range of 5 to 50 nmol L−1 in samples from the Mersey estuary near Liverpool and its potential use for in situ monitoring was demonstrated by using it to monitor labile iron (at 2–3 nmol L−1) over a period of 4 days at 1 h intervals in coastal waters in the Trondheim fjord, Norway.Keywords
This publication has 31 references indexed in Scilit:
- Continouos Heavy Metal Monitoring System for Application in River and SeawaterElectroanalysis, 2005
- Voltammetric Monitoring of Bivalent Iron in Waters and Effluents, Using a Dental Amalgam Sensor Electrode. Some Preliminary ResultsElectroanalysis, 2004
- Iron Speciation in the Trondheim Fjord from the Perspective of Iron Limitation for PhytoplanktonEstuarine, Coastal and Shelf Science, 2002
- Nafion Coated Electrodes as Voltammetric Sensors for Iron Analysis in Sediments and Pore Waters: an Example from the Lagoon of VeniceSensors, 2001
- Voltammetric characterization of a dissolved iron sulphide species by laboratory and field studiesAnalytica Chimica Acta, 1998
- Determination of iron in seawater by high-resolution isotope dilution inductively coupled plasma mass spectrometry after Mg(OH)2 coprecipitationAnalytica Chimica Acta, 1998
- What controls dissolved iron concentrations in the world ocean?Marine Chemistry, 1997
- Response to Comment on “Determination of Metal (Bi)Sulfide Stability Constants of Mn2+, Fe2+, Co2+, Ni2+, Cu2+, and Zn2+ by Voltammetric Methods”Environmental Science & Technology, 1996
- Development of a Gold Amalgam Voltammetric Microelectrode for the Determination of Dissolved Fe, Mn, O2, and S(-II) in Porewaters of Marine and Freshwater SedimentsEnvironmental Science & Technology, 1995
- The chemical speciation of dissolved nickel, copper, vanadium and iron in Liverpool Bay, Irish SeaEstuarine, Coastal and Shelf Science, 1989