A multichannel block-matching denoising algorithm for spectral photon-counting CT images
- 22 May 2017
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 44 (6) , 2447-2452
Abstract
We present a denoising algorithm designed for a whole-body prototype photon-counting computed tomography (PCCT) scanner with up to 4 energy thresholds and associated energy-binned images. Spectral PCCT images can exhibit low signal to noise ratios (SNRs) due to the limited photon counts in each simultaneously-acquired energy bin. To help address this, our denoising method exploits the correlation and exact alignment between energy bins, adapting the highly-effective block-matching 3D (BM3D) denoising algorithm for PCCT. The original single-channel BM3D algorithm operates patch-by-patch. For each small patch in the image, a patch grouping action collects similar patches from the rest of the image, which are then collaboratively filtered together. The resulting performance hinges on accurate patch grouping. Our improved multi-channel version, called BM3D_PCCT, incorporates two improvements. Firstly, BM3D_PCCT uses a more accurate shared patch grouping based on the image reconstructed from photons detected in all 4 energy bins. Secondly, BM3D_PCCT performs a cross-channel decorrelation, adding a further dimension to the collaborative filtering process. These two improvements produce a more effective algorithm for PCCT denoising. Preliminary results compare BM3D_PCCT against BM3D_Naive, which denoises each energy bin independently. Experiments use a three-contrast PCCT image of a canine abdomen. Within five regions of interest, selected from paraspinal muscle, liver, and visceral fat, BM3D_PCCT reduces the noise standard deviation by 65.0%, compared to 40.4% for BM3D_Naive. Attenuation values of the contrast agents in calibration vials also cluster much tighter to their respective lines of best fit. Mean angular differences (in degrees) for the original, BM3D_Naive, and BM3D_PCCT images, respectively, were 15.61, 7.34, and 4.45 (iodine); 12.17, 7.17, and 4.39 (galodinium); and 12.86, 6.33, and 3.96 (bismuth). We outline a multi-channel denoising algorithm tailored for spectral PCCT images, demonstrating improved performance over an independent, yet state-of-the-art, singlechannel approach.Keywords
Funding Information
- Intramural Research Program
- National Institutes of Health
This publication has 7 references indexed in Scilit:
- Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomographyPhysics in Medicine & Biology, 2016
- Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human ExperienceRadiology, 2016
- Joint reconstruction of multi-channel, spectral CT data via constrained total nuclear variation minimizationPhysics in Medicine & Biology, 2015
- Vision 20/20: Single photon counting x‐ray detectors in medical imagingMedical Physics, 2013
- CircStat: AMATLABToolbox for Circular Statistics2009
- Image Denoising by Sparse 3-D Transform-Domain Collaborative FilteringIEEE Transactions on Image Processing, 2007
- Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetry interest1995