Comparison of stone retropulsion between Moses mode and virtual basket mode: an in vitro study using artificial stones
- 7 June 2022
- journal article
- research article
- Published by Springer Nature in Urolithiasis
- Vol. 50 (4) , 493-499
Abstract
This study aimed to evaluate stone retropulsion in various laser pulse modes in both Moses mode (MM) and virtual basket mode (VBM). Experiments were performed using a channel-shaped rubber rail and artificial stones. We compared short pulse mode and long pulse mode in both MM and VBM with the laser tip positioned so that it was touching and at 1 and 2 mm distances from the stone surface. Stone retropulsion was measured after the laser fired for 10 s in three different laser settings: 0.5 J/8 Hz, 0.8 J/8 Hz and 1.0 J/8 Hz. When the laser tip was touching the artificial stone, stone retropulsion in MM was significantly shorter than that in VBM in all laser settings (P < 0.01, P = 0.02 and P = 0.02, respectively). At 1-mm distance, stone retropulsion in MM was significantly shorter than that in VBM in 0.8 J/8 Hz and 1.0 J/8 Hz settings (P < 0.01 and P = 0.01, respectively). At 2-mm distance, however, there were no differences between MM and VBM in stone retropulsion in any laser settings. Stone retropulsion was not significantly different between the laser settings at 1-mm distance in MM, or when touching in VBM. In conclusion, stone retropulsion distance in MM can be shorter than that in VBM. Stone retropulsion in MM and VBM may be differently influenced by laser settings and laser tip position.Keywords
This publication has 15 references indexed in Scilit:
- Moses technology in a stone simulatorCanadian Urological Association Journal, 2017
- Use of the Moses Technology to Improve Holmium Laser Lithotripsy Outcomes: A Preclinical StudyJournal of Endourology, 2017
- Contemporary Surgical Trends in the Management of Upper Tract CalculiJournal of Urology, 2015
- Effect of Pulse Width on Object Movement In Vitro Using Holmium:YAG LaserJournal of Endourology, 2007
- Dependence of calculus retropulsion on pulse duration during HO: YAG laser lithotripsyLasers in Surgery and Medicine, 2006
- Effect of Holmium:YAG Laser Pulse Width on Lithotripsy Retropulsion in VitroJournal of Endourology, 2005
- Ultracal-30 gypsum artificial stones for research on the mechanisms of stone breakage in shock wave lithotripsyUrological Research, 2005
- Dependence of Calculus Retropulsion Dynamics on Fiber Size and Radiant Exposure During Ho:YAG LithotripsyJournal of Biomechanical Engineering, 2004
- Stone Retropulsion During Holmium:Yag LithotripsyJournal of Urology, 2003
- Evaluation of Retropulsion Caused by Holmium: YAG Laser with Various Power Settings and FibersJournal of Endourology, 1998