Comparison of automated fastener device Cor-Knot versus manually-tied knot in minimally-invasive isolated aortic valve replacement surgery
- 1 February 2020
- journal article
- research article
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 61 (1) , 123-128
Abstract
The aim of our prospective study was to evaluate the efficacy and the safety of the Cor-Knot device in isolated aortic valve replacement by right anterior minithoracotomy. A single-center, prospective study was conducted between September 2009 and June 2018. Four hundred and forty patients were operated on for aortic valve replacement by right anterior minithoracotomy. Of these patients, 221 underwent isolated AVR surgery with stented prosthesis. Sutures were secured using the Cor-Knot titanium fastener in 63 patients (28.5%) and knots were hand-tied in 158 (71.5%). Statistical analyses were done using a propensity score with 1:1 matching for the automatically tied (AT) and manually tied (MT) patients. The aortic cross-clamping and cardiopulmonary bypass times were significantly decreased in the AT group (74±13.8 minutes vs. 90.4±23.7 minutes, P<0.0001, and 100.8±20.6 minutes vs. 117.6±33.1 minutes, P<0.0001), compared with the MT group. Clinical outcomes were similar in the two groups, whether in the analysis of non-matched or matched groups. There was no difference in 30 day-mortality (1.2% vs. 0%, P=0.37), and the stroke and transient ischemic attack rates were comparable (2.5% vs. 1.6%; P=0.67). There was no significant increase in pacemaker implantation in the AT group (1.3% vs. 0%, P=0.36), and the rate of aortic regurgitation ≥ 2 was lower (3.9% vs. 0%; P=0.11) but not statistically significant. The automated Cor-Knot fastener is an easy-to-use, time-saving device which does not increase perioperative morbidity and mortality in patients undergoing aortic valve replacement by right anterior minithoracotomy.Keywords
This publication has 18 references indexed in Scilit:
- Prolonged Cross-Clamping During Aortic Valve Replacement Is an Independent Predictor of Postoperative Morbidity and Mortality: Analysis of the Japan Cardiovascular Surgery DatabaseThe Annals of Thoracic Surgery, 2017
- A comparison of minimally invasive and standard aortic valve replacementThe Journal of Thoracic and Cardiovascular Surgery, 2016
- Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure MappingInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2016
- Automated fastener versus manually tied knots in minimally invasive mitral valve repair: impact on operation time and short- term resultsJournal of Cardiothoracic Surgery, 2015
- Right anterior minithoracotomy for aortic valve replacement: 10-year experience of a single centerThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Long-Term Durability of Bioprosthetic Aortic Valves: Implications From 12,569 ImplantsThe Annals of Thoracic Surgery, 2015
- Aortic valve replacement through full sternotomy with a stented bioprosthesis versus minimally invasive sternotomy with a sutureless bioprosthesisEuropean Journal of Cardio-Thoracic Surgery, 2015
- A Randomized Multicenter Trial of Minimally Invasive Rapid Deployment Versus Conventional Full Sternotomy Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2015
- A need for speed? Bypass time and outcomes after isolated aortic valve replacement surgeryInteractive CardioVascular and Thoracic Surgery, 2014
- Comparison of Strength, Consistency, and Speed of COR-KNOT versus Manually Hand-Tied Knots in an Ex Vivo Minimally Invasive ModelInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2014