AngioSuite: an accurate method to calculate aneurysm volumes and packing densities
Authors:
- 11 July 2012
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 5 (Suppl 3) , iii28-iii32
Abstract
Objective AngioSuite was developed to allow the easy and accurate calculation of cerebral aneurysm volumes and packing densities. The present study was undertaken to validate its accuracy. Methods Mathematical models and software were created to facilitate more complex aneurysm volume calculations than previously described three-dimensional geometric models. 20 phantom aneurysm clay models were created and analyzed (length, width, depth and volume) using angiographic mathematical modeling (AngioSuite), geometric modeling (AngioCalc) and three-dimensional volume reconstructions from the vendor's Leonardo workstation (Siemens). Results The mean volumes of all phantoms analyzed by the AngioSuite system differed from true volumes by an average of 2.2%. Mean volumes of all phantoms analyzed by the AngioCalc system differed from true volumes by an average of 11.3%. Mean volumes obtained from the Leonardo workstation windowed for best appearance differed by an average of 5.18%. Conclusions The AngioSuite software system provides an accurate means of calculating aneurysm volumes. Typical packing densities (40% or less) are thus accurate within ±1%. Angiographic mathematical modeling with AngioSuite is more accurate than geometric modeling and three-dimensional volume reconstructions windowed for best appearance (Leonardo).Keywords
This publication has 9 references indexed in Scilit:
- Comparison of Cerebral Aneurysm Volumes as Determined by Digitally Measured 3D Rotational Angiography and Approximation from Three DiametersInterventional Neuroradiology, 2011
- Mathematic Analysis of Incremental Packing Density with Detachable Coils: Does That Last Coil Matter Much?American Journal of Neuroradiology, 2011
- Current Imaging Assessment and Treatment of Intracranial AneurysmsAmerican Journal of Roentgenology, 2011
- Intracranial Aneurysms Coiling With MatrixStroke, 2009
- Intracranial Aneurysms: Treatment with Bare Platinum Coils—Aneurysm Packing, Complex Coils, and Angiographic RecurrenceRadiology, 2007
- Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated with CoilsRadiology, 2004
- Levene Tests of Homogeneity of Variance for General Block and Treatment DesignsBiometrics, 2002
- Endovascular Occlusion of Intracranial Aneurysms with Guglielmi Detachable Coils: Correlation Between Coil Packing Density and Coil CompactionActa Neurochirurgica, 2001
- Long-term Angiographic Follow-up of 169 Intracranial Berry Aneurysms Occluded with Detachable CoilsRadiology, 1999