Effectiveness of feedback with a smartwatch for high-quality chest compressions during adult cardiac arrest: A randomized controlled simulation study
Open Access
- 3 April 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (4) , e0169046
Abstract
Previous studies have demonstrated the potential for using smartwatches with a built-in accelerometer as feedback devices for high-quality chest compression during cardiopulmonary resuscitation. However, to the best of our knowledge, no previous study has reported the effects of this feedback on chest compressions in action. A randomized, parallel controlled study of 40 senior medical students was conducted to examine the effect of chest compression feedback via a smartwatch during cardiopulmonary resuscitation of manikins. A feedback application was developed for the smartwatch, in which visual feedback was provided for chest compression depth and rate. Vibrations from smartwatch were used to indicate the chest compression rate. The participants were randomly allocated to the intervention and control groups, and they performed chest compressions on manikins for 2 min continuously with or without feedback, respectively. The proportion of accurate chest compression depth (≥5 cm and ≤6 cm) was assessed as the primary outcome, and the chest compression depth, chest compression rate, and the proportion of complete chest decompression (≤1 cm of residual leaning) were recorded as secondary outcomes. The proportion of accurate chest compression depth in the intervention group was significantly higher than that in the control group (64.6±7.8% versus 43.1±28.3%; p = 0.02). The mean compression depth and rate and the proportion of complete chest decompressions did not differ significantly between the two groups (all p>0.05). Cardiopulmonary resuscitation-related feedback via a smartwatch could provide assistance with respect to the ideal range of chest compression depth, and this can easily be applied to patients with out-of-hospital arrest by rescuers who wear smartwatches.Keywords
Funding Information
- Bumsuk Academic Research Fund in 2015 (Bumsuk Academic Research Fund in 2015)
- Bumsuk Academic Research Fund in 2015 (Bumsuk Academic Research Fund in 2015)
- Bumsuk Academic Research Fund in 2015 (Bumsuk Academic Research Fund in 2015)
This publication has 33 references indexed in Scilit:
- What is the role of chest compression depth during out-of-hospital cardiac arrest resuscitation?*Critical Care Medicine, 2012
- An audiovisual feedback device for compression depth, rate and complete chest recoil can improve the CPR performance of lay persons during self-training on a manikinPhysiological Measurement, 2011
- Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trialBMJ, 2011
- A randomized trial of the capability of elderly lay persons to perform chest compression only CPR versus standard 30:2 CPRResuscitation, 2010
- New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrestResuscitation, 2010
- Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional studyResuscitation, 2006
- Predictors of cardiopulmonary resuscitation and automated external defibrillator skill retentionAmerican Heart Journal, 2005
- Skeletal chest injuries secondary to cardiopulmonary resuscitationResuscitation, 2004
- Effect of rescuer fatigue on performance of continuous external chest compressions over 3 minResuscitation, 2002
- Effect of advanced cardiac life-support training in rural, community hospitalsCritical Care Medicine, 1994