Special requirements of high frequency current transformers in the on-line detection of partial discharges in power cables
Authors:
- 26 October 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 32 (6) , 8-19
Abstract
The insulation condition of power cables is closely associated with partial discharge (PD) [1]. Early signs of cable insulation failure such as from electrical treeing are revealed by PD detection [2], and insulation failure will eventually lead to breakdown [3]-[5]. For AC cross-linked polyethylene (XLPE) cables, online PD detection is used to determine potential defects in the cable, and high frequency current transformers (HFCT) are most commonly applied for convenient and noninvasive detection. Conventional PD measuring techniques have been specified in IEC 60270 [6], and cable factory tests are based on this method. When PD detection is conducted on cables in service, some special issues such as noise reduction and dynamic range have to be dealt with [7]. Complex electromagnetic interferences and noise may significantly affect detection results by reducing the detection sensitivity [8]. Some high frequency components of PD signals cannot be covered by the detection bandwidth of a measuring instrument because the upper limit frequency is not high enough [9]. One more challenge is that a long cable can cause significant attenuation of PD signals [10]-[12], which will decrease the signal amplitudes to be detected. Therefore, the PD measuring instruments for on-line detection for cables have to satisfy some additional requirements.Keywords
This publication has 38 references indexed in Scilit:
- Effective partial discharge measurement method for XLPE cables based on propagation characteristics of high frequency signal2012
- For the Grid and Through the Grid: The Role of Power Line Communications in the Smart GridProceedings of the IEEE, 2011
- Advanced noise suppression during PD measurements by real-time pulse-waveform analysis of PD pulses and pulse-shaped disturbances2010
- PD detection in extruded power cables: an approximate propagation modelIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- High Frequency Attenuation in Transmission Class Solid Dielectric CableIEEE Transactions on Power Delivery, 2008
- Experiences in on-site partial discharge measurements and prospects for PD monitoring2008
- Partial Discharge Pulse Propagation in Shielded Power Cable and Implications for Detection SensitivityIEEE Electrical Insulation Magazine, 2007
- Bandwidth and sensitivity issues in PD detection in power cablesIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- High frequency properties of shielded power cable - part 1: overview of mechanismsIEEE Electrical Insulation Magazine, 2005
- Calibration for time domain propagation constant measurements on power cablesIEEE Transactions on Instrumentation and Measurement, 2003