Preflight Spectral Calibration of Airborne Shortwave Infrared Hyperspectral Imager with Water Vapor Absorption Characteristics
Open Access
Abstract
Due to the strong absorption of water vapor at wavelengths of 1350–1420 nm and 1820–1940 nm, under normal atmospheric conditions, the actual digital number (DN) response curve of a hyperspectral imager deviates from the Gaussian shape, which leads to a decrease in the calibration accuracy of an instrument’s spectral response functions (SRF). The higher the calibration uncertainty of SRF, the worse the retrieval accuracy of the spectral characteristics of the targets. In this paper, an improved spectral calibration method based on a monochromator and the spectral absorptive characteristics of water vapor in the laboratory is presented. The water vapor spectral calibration method (WVSCM) uses the difference function to calculate the intrinsic DN response functions of the spectral channels located in the absorptive wavelength range of water vapor and corrects the wavelength offset of the monochromator via the least-square procedure to achieve spectral calibration throughout the full spectral responsive range of the hyper-spectrometer. The absolute spectral calibration uncertainty is ±0.125 nm. We validated the effectiveness of the WVSCM with two tunable semiconductor lasers, and the spectral wavelength positions calibrated by lasers and the WVSCM showed a good degree of consistency.Keywords
Funding Information
- China High Resolution Earth Observation Project (Y1X19522N0)
This publication has 19 references indexed in Scilit:
- Research on the shortwave infrared hyperspectral imaging technology based on Integrated Stepwise filterInfrared Physics & Technology, 2017
- High spatial resolution shortwave infrared imaging technology based on time delay and digital accumulation methodInfrared Physics & Technology, 2017
- Laboratory spectral calibration and radiometric calibration of hyper-spectral imaging spectrometer2014
- Spectral Calibration of Hyperspectral Data Observed From a Hyperspectrometer Loaded on an Unmanned Aerial Vehicle PlatformIEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, 2014
- Calibration facility for airborne imaging spectrometersISPRS Journal of Photogrammetry and Remote Sensing, 2009
- Wavelength Calibration of Shortwave Infrared Flat SpectroradiometerActa Optica Sinica, 2008
- Spectral calibration of hyperspectral imagery using atmospheric absorption featuresApplied Optics, 2006
- On-orbit radiometric and spectral calibration characteristics of EO-1 Hyperion derived with an underflight of AVIRIS and in situ measurements at Salar de Arizaro, ArgentinaIEEE Transactions on Geoscience and Remote Sensing, 2003
- Simultaneous multigas detection with cascaded strongly gain coupled DFB laser by dual wavelength operationElectronics Letters, 2002
- The algorithm for MODIS wavelength on-orbit calibration using the SRCAIEEE Transactions on Geoscience and Remote Sensing, 2000