Abstract
The behavior of luminol electrochemiluminescence (ECL) at a paraffin-impregnated graphite electrode (PIGE) at different applied potentials was studied. Five ECL peaks were observed at 0.31, 0.59, 1.09, 1.54, and −0.58 V versus SCE, respectively, being related to potential scan direction and ranges, N2, O2, pH of the solution, and KCl concentration. The emission spectra of various ECL peaks at different potentials showed that all ECL peaks were initiated by luminol reactions. X-ray diffraction demonstrated that a simple mixture was formed between graphite and paraffin. The fluorescence spectra on the surface of the PIGE suggested that certain groups on the graphite were oxidized when the positive potential was applied to the electrode. In the presence of O2, three main ECL peaks were obtained in 0.1 mol/L KCl at pH 12.2. The ECL peak at 0.59 V with a shoulder is likely due to the reaction of luminol radicals with O2 and further electrooxidation of luminol radicals. The ECL peak at 1.54 V was suggested to be due to the electrooxidation of OH- to HO2- at higher potential and then to O2•-, which reacted with luminol to produce light emission. Moreover, the oxygen-containing functional groups formed by the oxidation of the surface of the graphite electrode might enhance the ECL. At −0.58 V, the dissolved oxygen in solution was reduced to HO2-, resulting in light emission. At a potential higher than 1.64 V, ClO- was formed, leading to a broad emission wave and enhancement of the ECL peak at −0.58 V upon the reversal scan. Under nitrogen atmosphere, an ECL peak appeared at 1.09 V. At this potential, OH- was oxidized to O2, followed by the reaction with luminol to generate light emission. At pH 13.2 or 0.5 mol/L KCl, the shoulder of the ECL peak at 0.59 V became an ECL peak at 0.31 V. The conversion of luminol radicals into excited 3-aminophthalate may undergo two routes. Under these conditions, two routes might proceed at a different rate to form another ECL peak. It is concluded that luminol ECL could be readily excited by various oxygen-containing species electrogenerated at different applied potentials. Three strong ECL peaks obtained at different potentials on the PIGE might be of a potential to improve analyticalselectivity and sensitivity for the detection of some analytes.Keywords
This publication has 7 references indexed in Scilit:
- Recent applications of electrogenerated chemiluminescence in chemical analysisTalanta, 2001
- Simulation of electrochemiluminescence produced by a high-frequency square-wave potential waveform. Effects of ohmic drop and cell time constant on electrode potential, current and light emissionJournal of Electroanalytical Chemistry, 1995
- Chemiluminescent tags in immunoassaysTrAC Trends in Analytical Chemistry, 1983
- The mechanism of the cobalt(II)-catalyzed electro-generated chemiluminescence of luminol in aqueous alkaline solutionAnalytica Chimica Acta, 1982
- Polymer films on electrodes. 4. Nafion-coated electrodes and electrogenerated chemiluminescence of surface-attached tris(2,2'-bipyridine)ruthenium(2+)Journal of the American Chemical Society, 1980
- Radiofrequency oxygen plasma treatment of pyrolytic graphite electrode surfacesAnalytical Chemistry, 1977
- Mechanism of the ferricyanide-catalyzed chemiluminescence of luminolThe Journal of Organic Chemistry, 1970