Abstract
NOWICKI, K. D., C. D. HUMMER III, R. S. HEIDT, JR., and A. J. COLOSIMO. Effects of iontophoretic versus injection administration of dexamethasone. Med. Sci. Sports Exerc., Vol. 34, No. 8, pp. 1294–1301, 2002. Sixty-eight skeletally mature New Zealand white rabbits were used to study the effects of iontophoresis- and injection-delivered sodium phosphate dexamethasone (DX) on the morphologic, histologic, microscopic, and biomechanical properties of uninjured rabbit patellar tendons over an initial 14-d period. Three control (untreated, placebo iontophoresis, and placebo injection) groups and two treatment (iontophoresis and injection) groups underwent serum, ELISA tendon, histology, electron microscopy, and biomechanical analysis. Serum DX levels were detectable and quantifiable in both treatment groups at 1 h but were significantly greater (P < 0.05) in the injected group (11.29 ng·mL−1) compared with the iontophoresis group (6.34 ng·mL−1). The most significant histologic finding was a lack of a cellular inflammatory response in the DX-treated groups at 24 h. Ultrastructural analysis produced no significant differences between size or size ratio of collagen fibrils among any groups. Morphologic examination revealed only injection puncture marks seen in appropriate tendons. Biomechanical testing produced disruption at the patellar insertion in 81% of the specimens. No injected tendon failed at the injection site. Normalized biomechanical properties included: 1) Stiffness increased in control and iontophoresis groups from 1 to 24 h, then gradually declined; the DX-injected specimens showed a similar but delayed effect. 2) Peak load at failure for iontophoresis and control groups was greatest at 24 h. The DX-injected group again showed a delayed response. 3) In general, total energy to failure revealed no significant differences between groups at any time period. It appears that iontophoresis or injection-delivered DX may produce anti-inflammatory effects without significantly altering ultrastructural or biomechanical characteristics of the rabbit patellar tendon within an initial 14-d period.Keywords
This publication has 31 references indexed in Scilit:
- Treatment of infrapatellar Tendinitis: A Combination of Modalities and Transverse Friction Massage versus IontophoresisJournal of Sport Rehabilitation, 1994
- A Prospective, Nonrandomized Study of Iontophoresis, Wrist Splinting, and Antiinflammatory Medication in the Treatment of Early-Mild Carpal Tunnel SyndromeJournal of Occupational and Environmental Medicine, 1994
- The mechanical properties of skeletally mature rabbit anterior cruciate ligament and patellar tendon over a range of strain ratesJournal of Orthopaedic Research, 1993
- LIGAMENTUM PATELLAE RUPTURE FOLLOWING LOCAL STEROID INJECTIONAnz Journal of Surgery, 1986
- Collagen Fibril Formation in the Presence of Dexamethasone Disodium PhosphateConnective Tissue Research, 1986
- Introduction of Antiinflammatory Drugs by Iontophoresis: Double Blind StudyJournal of Orthopaedic & Sports Physical Therapy, 1982
- The Quantity and Distribution of Radiolabeled Dexamethasone Delivered to Tissue by IontophoresisInternational Journal of Dermatology, 1980
- High Performance Liquid Chromatographic Assay of Dexamethasone in Plasma and TissueTherapeutic Drug Monitoring, 1980
- THE EFFECT OF INJECTION OF HYDROCORTISONE INTO RABBIT CALCANEAL TENDONSThe Journal of Bone and Joint Surgery. British volume, 1972
- Spontaneous rupture of the calcaneal tendon in rheumatoid arthritis after local steroid injection.Annals of the Rheumatic Diseases, 1970