Heart Rate Variability and Pulse Rate Variability: Do Anatomical Location and Sampling Rate Matter?
Open Access
Abstract
Wearable technology and neuroimaging equipment using photoplethysmography (PPG) have become increasingly popularized in recent years. Several investigations deriving pulse rate variability (PRV) from PPG have demonstrated that a slight bias exists compared to concurrent heart rate variability (HRV) estimates. PPG devices commonly sample at ~20–100 Hz, where the minimum sampling frequency to derive valid PRV metrics is unknown. Further, due to different autonomic innervation, it is unknown if PRV metrics are harmonious between the cerebral and peripheral vasculature. Cardiac activity via electrocardiography (ECG) and PPG were obtained concurrently in 54 participants (29 females) in an upright orthostatic position. PPG data were collected at three anatomical locations: left third phalanx, middle cerebral artery, and posterior cerebral artery using a Finapres NOVA device and transcranial Doppler ultrasound. Data were sampled for five minutes at 1000 Hz and downsampled to frequencies ranging from 20 to 500 Hz. HRV (via ECG) and PRV (via PPG) were quantified and compared at 1000 Hz using Bland–Altman plots and coefficient of variation (CoV). A sampling frequency of ~100–200 Hz was required to produce PRV metrics with a bias of less than 2%, while a sampling rate of ~40–50 Hz elicited a bias smaller than 20%. At 1000 Hz, time- and frequency-domain PRV measures were slightly elevated compared to those derived from HRV (mean bias: ~1–8%). In conjunction with previous reports, PRV and HRV were not surrogate biomarkers due to the different nature of the collected waveforms. Nevertheless, PRV estimates displayed greater validity at a lower sampling rate compared to HRV estimates.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2020-04057, CGSD3-559333–2021, 173416)
- Canadian Institutes of Health Research (RGPIN-2020-04057, CGSD3-559333–2021, 173416)
- University of Calgary (RGPIN-2020-04057, CGSD3-559333–2021, 173416)
- OpenBCI Sponsorship Scholarship (RGPIN-2020-04057, CGSD3-559333–2021, 173416)
This publication has 62 references indexed in Scilit:
- Consumer Wearable Health and Fitness Technology in Cardiovascular MedicineJACC, 2023
- Insufficient sampling frequencies skew heart rate variability estimates: Implications for extracting heart rate metrics from neuroimaging and physiological dataJournal of Biomedical Informatics, 2021
- World Medical Association Declaration of HelsinkiJAMA, 2013
- DCE‐MRI of the liver: Effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibilityJournal of Magnetic Resonance Imaging, 2013
- A comparative study of pulse rate variability and heart rate variability in healthy subjectsJournal of Clinical Monitoring and Computing, 2012
- Nonuniform sampling and spectral aliasingJournal of Magnetic Resonance, 2009
- What is inside the electrocardiograph?Journal of Electrocardiology, 2008
- Heart rate variability: a reviewMedical & Biological Engineering & Computing, 2006
- Hemodynamic Response to the Upright PostureThe Journal of Clinical Pharmacology, 1994
- Comparison of time- and frequency domain-based measures of cardiac parasympathetic activity in Holter recordings after myocardial infarctionThe American Journal of Cardiology, 1989