Scanning electron microscopic evaluation of the skin surface after ultrasound exposure
Open Access
- 1 April 1997
- journal article
- research article
- Published by Wiley in The Anatomical Record
- Vol. 247 (4) , 455-461
Abstract
Background Transdermal drug‐delivery systems have become widely accepted clinically for the administration of several systemic drugs. Recently, research on ultrasound irradiation to facilitate the penetration of drugs through the skin have been reported. The present study investigated the morphological changes induced in skin after ultrasound irradiation to hairless mouse skin and human skin. Methods Hairless mice and human skin were immersed in an ultrasound irradiation water tank. Ultrasound was delivered for a duration of 5 min. Ultrasound frequency of 48 kHz was generated at an intensity of 0.5 W/cm2. The surface of the skin was observed with scanning electron microscopy for comparison with skin samples unexposed to ultrasound energy. Results For hairless mouse exposed to ultrasound, the cells of the stratum corneum of the skin surface were almost completely removed. The polygonal cells of the stratum spinosum and basal cells were exposed. In addition, large craterlike pores with a diameter of 100 μm were formed sporadically in some of the skin samples. In contrast, the surface of human skin exposed to ultrasound showed only slight removal of keratinocytes around the hair follicles. Conclusion The removal of the stratum corneum and other alterations in hairless mouse and human skin by ultrasound may explain the enhancement of transdermal drug penetration. The effect on human skin was relatively minor compared with that on hairless mouse skin. Anat. Rec. 247:455–461, 1997.Keywords
This publication has 16 references indexed in Scilit:
- Ultrasound-Mediated Transdermal Protein DeliveryScience, 1995
- High-Frequency Sonophoresis: Permeation Pathways and Structural Basis for Enhanced PermeabilitySkin Pharmacology and Physiology, 1994
- Sonophoresis. I. The Use of High-Frequency Ultrasound to Enhance Transdermal Drug DeliveryPharmaceutical Research, 1992
- Effect of ultrasound on transdermal drug delivery to rats and guinea pigs.Journal of Clinical Investigation, 1989
- Use of Ultrasound to Enhance Percutaneous Absorption of BenzydaminePhysical Therapy, 1989
- The Effect of Ultrasound on the in Vitro Penetration of Ibuprofen Through Human EpidermisPharmaceutical Research, 1989
- Successful transdermal administration of therapeutic doses of a polypeptide to normal human volunteersClinical Pharmacology & Therapeutics, 1988
- Lack of Effect of Ultrasound on the Percutaneous Absorption of BenzydamineJournal of Pharmacy and Pharmacology, 1986
- Control of Blood Glucose Levels in Alloxan-diabetic Rabbits by Iontophoresis of InsulinDiabetes, 1986
- A Comparative Study: Patients Treated with Ultrasonic Driven Hydrocortisone and with Ultrasound AlonePhysical Therapy, 1967