Abstract
Background: It is unclear whether clinical benefits of cardiac resynchronization can be achieved by pacing only the left ventricle.Hypothesis: We aimed to compare the effect of a novel adaptive left ventricular‐only fusion pacing (LVP) on ventricular function with conventional biventricular pacing (BVP) in cardiac resynchronization therapy (CRT) indicated patients.Methods: This prospective, randomized, multicenter study enrolled CRT‐indicated patients with PR interval ≤ 200 ms who were randomized in the adaptive LVP group (using the AdaptivCRT™ algorithm with intentional non‐capture right ventricular pacing) or the echocardiography‐optimized BVP group. Cardiac function and echocardiography were evaluated at baseline and follow‐ups. CRT super response was defined as two‐fold or more increase of left ventricular ejection fraction (LVEF) or final LVEF >45%, and LV end‐systolic volume (LVESV) decrease >15%, and New York Heart Association (NYHA) class improved by at least one level.Results: Sixty‐three patients were enrolled in the study (LVP = 34 vs. BVP = 29). At 6‐month follow‐up, significant improvements in LVEF, LVESV, and NYHA class were observed in both groups. The CRT super response rate was significantly higher in patients with high‐percentage adaptive LV‐only pacing in LVP group (68.4%) than in BVP group (36.4%, p = .04).Conclusions: Adaptive LV‐only pacing was comparable to BVP in improving cardiac function and clinical condition in CRT‐indicated patients. This finding raises the possibility that an adaptive LVP algorithm with appropriate right ventricular sensing to fuse with intrinsic right ventricular activation in a two‐lead (right atrium and left ventricle) device may provide clinical benefit in a subset of CRT patients with intact atrioventricular conduction.Keywords
Funding Information
- Medtronic
This publication has 16 references indexed in Scilit:
- Continuous optimization of cardiac resynchronization therapy reduces atrial fibrillation in heart failure patients: Results of the Adaptive Cardiac Resynchronization Therapy TrialHeart Rhythm, 2017
- Clinical outcomes with synchronized left ventricular pacing: Analysis of the adaptive CRT trialHeart Rhythm, 2013
- Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: Results of the adaptive CRT trialHeart Rhythm, 2012
- A novel algorithm for individualized cardiac resynchronization therapy: Rationale and design of the adaptive cardiac resynchronization therapy trialAmerican Heart Journal, 2012
- Left Ventricular Versus Simultaneous Biventricular Pacing in Patients With Heart Failure and a QRS Complex ≥120 MillisecondsCirculation, 2011
- A randomized double-blind comparison of biventricular versus left ventricular stimulation for cardiac resynchronization therapy: The Biventricular versus Left Univentricular Pacing with ICD Back-up in Heart Failure Patients (B-LEFT HF) trialAmerican Heart Journal, 2010
- Reduced Ventricular Volumes and Improved Systolic Function With Cardiac Resynchronization TherapyCirculation, 2007
- The Hemodynamic Effect of Intrinsic Conduction During Left Ventricular Pacing as Compared to Biventricular PacingJACC, 2005
- Combined Cardiac Resynchronization and Implantable Cardioversion Defibrillation in Advanced Chronic Heart FailureJAMA, 2003
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002