Effect of Loading Rate on Environmentally Controlled Cracking of Sensitized 304 Stainless Steel in High Purity Water
Authors:
- F. P. FordFFF. P. Ford
- 1 November 1980
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 36 (11) , 597-603
Abstract
The environmentally-controlled crack propagation rates in the sensitized 304 stainless steel/water system at 95 C have been measured under static, monotonic; and cyclic stress conditions. It has been observed that the crack propagation rates increase with stress intensity rate and that the behavior under classical “stress corrosion” and “corrosion fatigue” conditions are quantitatively inter relatable. Of design importance, it is demonstrated that rapid loading times or even relatively small vibrations on a high mean load, are deleterious, even when the maximum stress intensity (KMAX) is below the threshold stress intensity (KISCC) measured under static loading conditions.Keywords
This publication has 3 references indexed in Scilit:
- The Effect of Oxygen Temperature Combinations on the Stress Corrosion Susceptibility of Sensitized Type 304 Stainless Steel in High Purity WaterCorrosion, 1979
- Intergranular Corrosion Fatigue Crack Growth of Sensitized Type 304 Stainless Steel in Oxygenated Pure Water at 85 CCorrosion, 1978
- Stress corrosion crack propagation: A constant charge criterionCorrosion Science, 1975