Impact of general anesthesia on ablation catheter stability during pulmonary vein isolation based on a novel measurement approach
Authors:
Open Access
- 11 October 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Abstract
Catheter ablation for atrial fibrillation (AF) during pulmonary vein isolation (PVI) is performed under general anesthesia (GA) or conscious sedation (CS). GA during PVI may improve treatment outcomes by improving catheter stability. However, the magnitude of GA-derived catheter stability compared with that of CS is unclear. We directly assessed catheter movement and determined the impact of GA compared with that of CS on ablation catheter stability during PVI. Patients who underwent initial ablation using the EnSite Precision™ mapping system were recruited and divided into two groups (GA and CS groups). The two groups were compared for ablation catheter stability during PVI based on the distance traveled by the catheter distal tip per second, clinical periprocedural characteristics, and periprocedural complications. Among 69 consecutively admitted patients, data of 30 patients (17 in the GA group and 13 in the CS group) and the distance traveled per second by the catheter on 148,976 points/patient were evaluated. The GA group had a significantly smaller catheter tip travel distance than the CS group (0.92 [0.82‒1.16] vs. 1.25 [1.14‒1.38], p = 0.01). Therefore, GA during PVI for AF provides greater catheter stability than CS and will contribute to more accessible and safer PVI procedures.Keywords
All Related Versions
This publication has 15 references indexed in Scilit:
- Pain Reactions during Pulmonary Vein Isolation under Deep Sedation: Cryothermal versus Radiofrequency AblationPacing and Clinical Electrophysiology, 2016
- Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2016
- Contact Force in Atrial Fibrillation: Role of Atrial Rhythm and Ventricular ContractionsCirculation: Arrhythmia and Electrophysiology, 2015
- EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillationEP Europace, 2015
- 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial DesignHeart Rhythm, 2012
- General anesthesia reduces the prevalence of pulmonary vein reconnection during repeat ablation when compared with conscious sedation: Results from a randomized studyHeart Rhythm, 2011
- Acute and Chronic Pulmonary Vein Reconnection after Atrial Fibrillation Ablation: A Prospective Characterization of Anatomical SitesPacing and Clinical Electrophysiology, 2008
- Pain and Anatomical Locations of Radiofrequency Ablation as Predictors of Esophageal Temperature Rise During Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2007
- Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary VeinsCirculation, 2000
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998