Mutations affect the quantification of SARS-CoV-2 in wastewater: observations, mechanisms, and recommendations
Authors:
Preprint
- 22 December 2023
- preprint
- Published by Springer Nature in Research Square
Abstract
Wastewater surveillance is an effective tool for monitoring community spread of covid-19 and other diseases. Quantitative PCR (qPCR) analysis for wastewater surveillance is more susceptible than binary PCR analysis for clinical surveillance to mutations in target genome regions. The SARS-CoV-2 concentrations in wastewater estimated by N1 and N2 qPCR assays started to diverge around July 2022 in data from different sampling sites, analytical methods, and analytical laboratories in Japan. On the basis of clinical genomic surveillance data and experimental data, we demonstrate that the divergence is due to two mutations in the N1 probe region, which can cause underestimation of viral concentrations. We further show that this inaccuracy can be alleviated if the qPCR data are analyzed with the second derivative method or the Cy0 method instead of the crossing point method.Keywords
All Related Versions
This publication has 21 references indexed in Scilit:
- A direct capture method for purification and detection of viral nucleic acid enables epidemiological surveillance of SARS-CoV-2Science of The Total Environment, 2021
- Efficient detection of SARS-CoV-2 RNA in the solid fraction of wastewaterScience of The Total Environment, 2021
- Detection of SARS-CoV-2 in wastewater in Japan during a COVID-19 outbreakScience of The Total Environment, 2021
- COVID-19 CG enables SARS-CoV-2 mutation and lineage tracking by locations and dates of interesteLife, 2021
- Viral load dynamics and disease severity in patients infected with SARS-CoV-2 in Zhejiang province, China, January-March 2020: retrospective cohort studyBMJ, 2020
- Virological assessment of hospitalized patients with COVID-2019Nature, 2020
- The Effect of Primer-Template Mismatches on the Detection and Quantification of Nucleic Acids Using the 5′ Nuclease AssayThe Journal of Molecular Diagnostics, 2010
- Studying the effect of single mismatches in primer and probe binding regions on amplification curves and quantification in real-time PCRJournal of Microbiological Methods, 2009
- Critical evaluation of methods used to determine amplification efficiency refutes the exponential character of real-time PCRBMC Molecular Biology, 2008
- A new real-time PCR method to overcome significant quantitative inaccuracy due to slight amplification inhibitionBMC Bioinformatics, 2008