A microbore high performance liquid chromatography/electrospray ionization mass spectrometry method for the determination of the phytoestrogens genistein and daidzein in comminuted baby foods and soya flour

Authors:

Abstract
A microbore high performance liquid chromatographic/electrospray/mass spectrometric (HPLC/ESI‐MS) method has been developed for the determination of the phytoestrogens daidzein and genistein in soya flours and baby foods. The samples were hydrolysed and extracted with acetonitrile–water prior to analysis. LC was performed on a microbore Primesphere 5C8 column using a water/acetonitrile/acetic acid mobile phase at a flow rate of 60 μl/min. Atmospheric pressure ionization in the form of pneumatically assisted electrospray mass spectrometry (ESI‐MS) was used as the method of detection. The limit of detection was 0.2 mg/kg for daidzein and 0.7 mg/kg for genistein in the flour and food samples. The method proved both robust and reliable when operated over a long time period (10 days, 463 injections) generating precision data with a coefficient of variation of 4–15%. © Crown Copyright