A practical approach to cerebral near‐infrared spectroscopy (NIRS) directed hemodynamic management in noncardiac pediatric anesthesia
Authors:
Open Access
- 22 August 2019
- journal article
- research article
- Published by Wiley in Pediatric Anesthesia
- Vol. 29 (10) , 993-1001
Abstract
Safeguarding cerebral function is of major importance during pediatric anesthesia. Premature, ex‐premature, and full‐term neonates can be vulnerable to physiological changes that occur during anesthesia and surgery. Data from studies performed during pediatric cardiac surgery and in neonatal/pediatric intensive care units have shown the benefits of near‐infrared spectroscopy (NIRS) monitoring of regional cerebral oxygenation (c‐rSO2). However, NIRS monitoring is seldom used during noncardiac pediatric anesthesia. Despite compelling evidence that blood pressure does not reflect end‐organ perfusion, it is still regarded as the most important determinant of cerebral perfusion and the most relevant hemodynamic management target parameter by most (pediatric) anesthetists. The principle of NIRS monitoring is not self‐explanatory and sometimes seems even counterintuitive, which may explain why many anesthesiologists are reserved regarding its use. The first part of this paper is dedicated to a clinical introduction to NIRS monitoring. Despite scientific efforts, it has not yet been possible to define individual lower limit c‐rSO2 values and it is unlikely this will succeed in the near future. Nonetheless, published treatment algorithms usually specify c‐rSO2 values which may be associated with cerebral hypoxia. Our treatment guideline for maintaining sufficient cerebral oxygenation differs fundamentally from all previously published approaches. We define a baseline c‐rSO2 value, registered in the awake child prior to anesthesia induction, as the lowest acceptable limit during anesthesia and surgery. The cerebral rSO2 is the single target parameter, while blood pressure, heart rate, PaCO2, and SaO2 are major parameters that determine the c‐rSO2. Cerebral NIRS monitoring, interpreted together with its continuously available contributing parameters, may help avoid potentially harmful episodes of cerebral desaturation in anesthetized pediatric patients.Keywords
This publication has 63 references indexed in Scilit:
- Impact of sevoflurane anesthesia on cerebral blood flow in children younger than 2 yearsPediatric Anesthesia, 2013
- Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applicationsJournal of Clinical Monitoring and Computing, 2012
- Has the time come to use near-infrared spectroscopy as a routine clinical tool in preterm infants undergoing intensive care?Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Effects of arterial blood gas levels on cerebral blood flow and oxygen transportBiomedical Optics Express, 2011
- Decreased cerebral oxygen saturation during thoracoscopic repair of congenital diaphragmatic hernia and esophageal atresia in infantsJournal of Pediatric Surgery, 2011
- Packed Red Blood Cell Transfusion Increases Regional Cerebral and Splanchnic Tissue Oxygen Saturation in Anemic Symptomatic Preterm InfantsAmerican Journal of Perinatology, 2010
- Cerebral Oxygen Saturation-Time Threshold for Hypoxic-Ischemic Injury in PigletsAnesthesia & Analgesia, 2009
- The effect of changes in tPCO2 on the fractional tissue oxygen extraction – as measured by near-infrared spectroscopy – in neonates during the first days of lifeEuropean Journal of Paediatric Neurology, 2009
- Brain magnetic resonance imaging abnormalities after the Norwood procedure using regional cerebral perfusionThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Near-Infrared Spectroscopy Cerebral Oxygen Saturation Thresholds for Hypoxia–Ischemia in PigletsJournal of Cerebral Blood Flow & Metabolism, 2002