Mechanical and Metallurgical Evaluation of Four Rotary Nickel‐Titanium File Systems: A Multimethod Study
Open Access
- 3 August 2026
- journal article
- research article
- Published by Wiley in International Endodontic Journal
- Vol. 59 (12) , 2741-2751
Abstract
Aim: To compare four rotary nickel‐titanium (NiTi) file systems (Endostar E3 Azure, Endostar E3, VDW.ROTATE, and Mtwo) using a multimethod approach to evaluate their mechanical and metallurgical properties. Materials and Methods: Endostar E3 Azure, Endostar E3, VDW.ROTATE, and Mtwo (all size 25/0.06 with an S‐shaped cross‐section; 52 instruments per system) were evaluated. Mechanical performance was assessed through static and dynamic cyclic fatigue tests (each treated as a separate and independent test model) together with torsional resistance, bending and buckling tests; the number of cycles to fracture (NCF) was used to compare cyclic fatigue resistance across systems operated at different rotational speeds. Metallurgical characterisation included scanning electron microscopy (SEM) for fractographic and surface analysis, energy‐dispersive X‐ray spectroscopy (EDS) for surface elemental composition, and differential scanning calorimetry (DSC) for phase‐transformation temperatures. Results: Endostar E3 Azure and VDW.ROTATE recorded the highest cyclic fatigue resistance and did not differ from each other within the fatigue models; both surpassed the conventional‐alloy instruments ( p < 0.05). In the static model, Endostar E3 and Mtwo did not differ from each other ( p > 0.05). Endostar E3 yielded the highest maximum torque (0.63 ± 0.01 Ncm), bending force (13.84 ± 1.79 gF) and buckling load (14.37 ± 4.13 gF; p < 0.05), whereas VDW.ROTATE showed the greatest angular deflection (577.03° ± 98.59°; p < 0.05). DSC revealed R‐phase‐mediated multi‐step transformations in the heat‐treated files, with austenite finish (Af) temperatures near body temperature; the conventional‐alloy files exhibited a single low‐intensity peak consistent with a wholly austenitic state. EDS detected surface oxygen on the thermomechanically processed files, indicating the presence of a TiO 2 layer. Conclusions: Thermomechanically processed systems exhibited greater flexibility and longer fatigue life, whereas conventional NiTi instruments demonstrated higher rigidity and torque capacity. DSC‐based phase characterisation was consistent with the divergent mechanical outcomes observed among groups and offered a plausible metallurgical explanation, although the contributions of alloy processing and instrument design could not be separated within the present study design.Keywords
This publication has 34 references indexed in Scilit:
- Multimethod assessment of design, mechanical and metallurgical characteristics of ProTaper Ultimate, TruNatomy Glider, ProGlider, Hyflex EDM and WaveOne Gold Glider glide path instrumentsOdontology, 2025
- Advancing Nitinol: From heat treatment to surface functionalization for nickel–titanium (NiTi) instruments in endodonticsBioactive Materials, 2022
- Comparison of cyclic fatigue resistance of Rotate instrument with reciprocating and continuous rotary nickel–titanium instruments at body temperature in relation to their transformation temperaturesClinical Oral Investigations, 2020
- Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc FilesJournal of Endodontics, 2017
- Blue Treatment Enhances Cyclic Fatigue Resistance of Vortex Nickel-Titanium Rotary FilesJournal of Endodontics, 2014
- Torsional Strength and Toughness of Nickel-Titanium Rotary FilesJournal of Endodontics, 2011
- Prevalence and Management of Instrument Fracture in the Postgraduate Endodontic Program at the Dental School of Athens: A Five-year Retrospective Clinical StudyJournal of Endodontics, 2008
- Effect of Immersion in Sodium Hypochlorite on Torque and Fatigue Resistance of Nickel-Titanium InstrumentsJournal of Endodontics, 2007
- Impact of Lubricant Parameters on Rotary Instrument Torque and ForceJournal of Endodontics, 2007
- Cyclic Fatigue of Three Types of Rotary Nickel-Titanium Files in a Dynamic ModelJournal of Endodontics, 2006