Arrhythmia Detection in Single‐ and Dual‐Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better?
- 26 August 2009
- journal article
- review article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 20 (9) , 1077-1082
Abstract
The implantable cardioverter defibrillator (ICD) offers life‐saving therapies for primary and secondary prevention of sudden cardiac death in high‐risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single‐chamber ICD (Sc‐ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachycardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual‐chamber ICDs (Dc‐ICDs) are supposed to overcome specificity issues by enhancing detection algorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc‐ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc‐ICDs in a more selective use of aggressive therapies. Despite this solid background, superiority of Dc‐ over Sc‐ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc‐ICDs in preventing inappropriate therapies.Keywords
This publication has 32 references indexed in Scilit:
- Prognostic Importance of Defibrillator Shocks in Patients with Heart FailureNew England Journal of Medicine, 2008
- Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart ratesEP Europace, 2008
- Dual-chamber defibrillators reduce clinically significant adverse events compared with single-chamber devices: results from the DATAS (Dual chamber and Atrial Tachyarrhythmias Adverse events Study) trialEP Europace, 2008
- Prevention of inappropriate therapy in implantable defibrillators: A meta-analysis of clinical trials comparing single-chamber and dual-chamber arrhythmia discrimination algorithmsInternational Journal of Cardiology, 2008
- Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillatorsHeart Rhythm, 2006
- Clinical variables predicting inappropriate use of implantable cardioverter-defibrillator in patients with coronary heart disease or nonischemic dilated cardiomyopathyThe American Journal of Cardiology, 2005
- The 1+1 TrialCirculation, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- Inappropriate Defibrillator Therapies: Are Dual Chamber Devices Providing a Remedy?Journal of Cardiovascular Electrophysiology, 2001
- A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1999