Influence of Ocular Biometry Parameters on the Predictive Accuracy of IOL Power Formulas in Patients with High Myopia
Authors:
Open Access
- 4 December 2023
- journal article
- research article
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (1) , 435-448
Abstract
Introduction The aim of this study was to investigate the influence of ocular biometry parameters on the predictive accuracy of 10 intraocular lens (IOL) power formulas in patients with high myopia (HM). Methods We analyzed 202 eyes of 202 patients. The ocular biometry was determined preoperatively using an IOLMaster 700. The associations between the biometry parameters and the prediction error (PE) 1 month postoperatively were assessed. HM was defined as an axial length exceeding 26.50 mm. Results In patients with HM (n = 108), the K6, Emmetropia Verifying Optical (EVO), Olsen, and Barrett Universal II (BUII) formulas had the lowest absolute PEs among the 10 formulas. The ocular biometry parameters were not associated with the PE of K6, EVO, Olsen, or BUII. A longer axial length in HM eyes was associated with myopic outcomes by Kane, Hoffer QST, and VRF and hyperopic outcomes by Holladay 2 and T2. Steeper keratometry, a deeper anterior chamber, and a thicker lens were associated with a hyperopic shift in HM eyes when using VRF, Kane, and Hoffer QST, respectively. In patients without HM (n = 94), there was no difference between the formulas in absolute PE. The significant associations between the biometry parameters and PE in patients with HM were not present in patients without HM. Conclusions K6, EVO, Olsen, and BUII displayed high accuracy in HM eyes and were not influenced by preoperative biometry parameters. For the remaining formulas, the preoperative keratometry, anterior chamber depth, lens thickness, and axial length were possible error sources underlying an inaccurate IOL power prediction in patients with HM.Keywords
Funding Information
- National Natural Science Foundation of China (81970780, 81670835, 82101103)
- Scientific Research Projects of the Shanghai Science and Technology Commission (19ZR1408600, 22ZR1410400)
- Shanghai Shenkang Hospital Development Center/Joint Research Project of New Frontier Technology in Municipal Hospitals (SHDC12020111)
This publication has 43 references indexed in Scilit:
- The effect of ocular biometric factors on the accuracy of various IOL power calculation formulasBMC Ophthalmology, 2017
- Association between Myopia, Biometry and Occludable Angle: The Jiangning Eye StudyPLOS ONE, 2016
- High myopia and cataract surgeryCurrent Opinion in Ophthalmology, 2016
- Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgeryJournal of Cataract & Refractive Surgery, 2015
- Postoperative refractive error after phacovitrectomy for epiretinal membrane with and without macular oedemaGraefe's Archive for Clinical and Experimental Ophthalmology, 2015
- Corneal Asphericity and Its Related Factors in 1052 Chinese SubjectsOptometry and Vision Science, 2011
- Topography-based assessment of anterior corneal curvature and asphericity as a function of age, sex, and refractive statusJournal of Cataract & Refractive Surgery, 2009
- G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciencesBehavior Research Methods, 2007
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- Group refractive index measurement by Michelson interferometerOptics Communications, 1990