Antibody affinity as a driver of signal generation in a paper-based immunoassay for Ebola virus surveillance
Authors:
- 14 April 2021
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (14) , 3695-3706
Abstract
During epidemics, such as the frequent and devastating Ebola virus outbreaks that have historically plagued regions of Africa, serological surveillance efforts are critical for viral containment and the development of effective antiviral therapeutics. Antibody serology can also be used retrospectively for population-level surveillance to provide a more complete estimate of total infections. Ebola surveillance efforts rely on enzyme-linked immunosorbent assays (ELISAs), which restrict testing to laboratories and are not adaptable for use in resource-limited settings. In this manuscript, we describe a paper-based immunoassay capable of detecting anti-Ebola IgG using Ebola virus envelope glycoprotein ectodomain (GP) as the affinity reagent. We evaluated seven monoclonal antibodies (mAbs) against GP—KZ52, 13C6, 4G7, 2G4, c6D8, 13F6, and 4F3—to elucidate the impact of binding affinity and binding epitope on assay performance and, ultimately, result interpretation. We used biolayer interferometry to characterize the binding of each antibody to GP before assessing their performance in our paper-based device. Binding affinity (KD) and on rate (kon) were major factors influencing the sensitivity of the paper-based immunoassay. mAbs with the best KD (3–25 nM) exhibited the lowest limits of detection (ca. μg mL−1), while mAbs with KD > 25 nM were undetectable in our device. Additionally, and most surprisingly, we determined that observed signals in paper devices were directly proportional to kon. These results highlight the importance of ensuring that the quality of recognition reagents is sufficient to support desired assay performance and suggest that the strength of an individual’s immune response can impact the interpretation of assay results. Graphical abstractKeywords
Funding Information
- National Institute of Allergy and Infectious Diseases (DP2AI124384)
- Tufts University
- Division of Chemical, Bioengineering, Environmental and Transport Systems (1846846)
This publication has 46 references indexed in Scilit:
- Patterned Paper as a Low-Cost, Flexible Substrate for Rapid Prototyping of PDMS Microdevices via “Liquid Molding”Analytical Chemistry, 2011
- Methods for the determination of limit of detection and limit of quantitation of the analytical methodsChronicles of Young Scientists, 2011
- Programmable diagnostic devices made from paper and tapeLab on a Chip, 2010
- Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices2009
- Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based MicrofluidicsAnalytical Chemistry, 2009
- Immunoglobulin G in Ebola Outbreak Survivors, GabonEmerging Infectious Diseases, 2009
- Infection in Man, FranceEmerging Infectious Diseases, 2009
- Structure of the Ebola virus glycoprotein bound to an antibody from a human survivorNature, 2008
- Surface Tailoring for Controlled Protein Adsorption: Effect of Topography at the Nanometer Scale and ChemistryJournal of the American Chemical Society, 2006
- Clinical Virology of Ebola Hemorrhagic Fever (EHF): Virus, Virus Antigen, and IgG and IgM Antibody Findings among EHF Patients in Kikwit, Democratic Republic of the Congo, 1995The Journal of Infectious Diseases, 1999