Abstract
Used engine oils (UEO) represent valuable secondary hydrocarbon resource. Nevertheless, their purification is hindered by degradation products, metal impurities, and high-molecular-weight components. In this paper, a comprehensive comparison of single- and two-stage ultrafiltration of UEOs using flat-sheet asymmetric poly(acrylonitrile-co-methyl acrylate) membranes with pore sizes of 25 nm (PAN25) and 5 nm (PAN5) was conducted for the first time. Single-stage filtration was performed through the PAN5 membrane, whereas the two-stage process involved sequential filtration through PAN25 and PAN5. Results showed that single-stage filtration through the PAN5 membrane ensures effective removal of resins, aromatic compounds, metal impurities, oil aging products. Resin and aromatic contents decreased by 47.2 wt.% and 37.2 wt.%, respectively, the total acid number (TAN) decreased from 3.3 to 0.58 mgKOH/g, and saturates content reached 91.6 wt.%. Preliminary filtration through the PAN25 membrane removes some pollutants, enabling deeper purification during the second stage. The overall reduction in resins and aromatics reached 71.7 wt.% and 44.0 wt.%, respectively. TAN decreased to 0.46 mgKOH/g, and saturates reached 93.3 wt.%. FTIR, CHNSO, ICP-AES, and SARA analysis confirmed the effective removal of undesirable compounds. Both purified products exhibited physicochemical properties comparable to light base oils with viscosities of 4–6 cSt (at 100 °C). The two-stage process reduced duration almost twofold, decreased the irreversible fouling ratio by a factor of 12, and improved purification efficiency. These results demonstrate the potential of cascade ultrafiltration using PAN membranes for developing energy-efficient UEO purification technologies.Keywords
This publication has 53 references indexed in Scilit:
- Comprehensive investigation of various re-refining technologies of used lubricating oil: a reviewJournal of Material Cycles and Waste Management, 2023
- Critical retrospection and evaluation of waste engine oil recycling methodsInternational Journal of Energy and Water Resources, 2023
- Effect of Waste-Oil regenerant on diffusion and fusion behaviors of asphalt recycling using molecular dynamics simulationConstruction and Building Materials, 2022
- Recycling of waste engine oil through pyrolysis process for the production of diesel like fuel and its uses in diesel engineEnergy, 2020
- Research on the development and regeneration performance of asphalt rejuvenator based on the mixed waste engine oil and waste cooking oilInternational Journal of Pavement Research and Technology, 2019
- Recycling of used engine oil by different solventEgyptian Journal of Petroleum, 2018
- Alcohol reduction in red and white wines by nanofiltration of musts before fermentationFood and Bioproducts Processing, 2015
- A property-integration approach to solvent screening and conceptual design of solvent-extraction systems for recycling used lubricating oilsClean Technologies and Environmental Policy, 2012
- Production of diesel-like fuel from waste engine oil by pyrolitic distillationApplied Energy, 2010
- Pyrolysis and combustion of waste lubricant oil from diesel cars: Decomposition and pollutantsJournal of Analytical and Applied Pyrolysis, 2007