Effect of Electrolyte pH on Crack Propagation in Glass
Authors:
- 1 April 1973
- journal article
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 56 (4) , 192-197
Abstract
Crack velocities in glass in various acids, bases, and neutral solutions were studied using the double‐cantilever‐beam technique. Results are explained in terms of crack‐tip pH, which is controlled by the electrolyte at low crack velocities and by the glass composition at high velocities. The crack‐velocity data are consistent with the known dependence of strength on pH for soda‐lime silicate glass. Results also suggest that the slope of the universal fatigue curve should depend on surface pH.Keywords
This publication has 11 references indexed in Scilit:
- A Chemical Interpretation of Static FatigueJournal of the American Ceramic Society, 1972
- Compatibility of Bioceramics with the Physiological Environment1971
- Effect of a Reactive Environment on the Hertzian Strength of Brittle SolidsJournal of Applied Physics, 1970
- Critical Analysis of the Theory of the Double Cantilever Method of Measuring Fracture-Surface EnergiesJournal of Applied Physics, 1968
- The strength of fused silicaProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1967
- The Strength of Inorganic Glasses1967
- Reactions of Glasses with Aqueous SolutionsJournal of the American Ceramic Society, 1967
- Strength and Static Fatigue of Abraded Glass Under Controlled Ambient Conditions: IV, Effect of Surrounding MediumJournal of the American Ceramic Society, 1961
- Strength and Static Fatigue of Abraded Glass Under Controlled Ambient Conditions: II, Effect of Various Abrasions and the Universal Fatigue CurveJournal of the American Ceramic Society, 1959
- Studies of the chemical durability of glass by an interferometer methodJournal of Research of the National Bureau of Standards, 1941