In Vitro Comparison of Bioactive Silicon Nitride Laser Claddings on Different Substrates
Authors:
- Elia MarinElia Marin
- Matteo ZanoccoMZMatteo Zanocco
- Francesco BoschettoFrancesco Boschetto
- Toshiro YamamotoTYToshiro Yamamoto
- Narisato KanamuraNKNarisato Kanamura
- Wenliang ZhuWZWenliang Zhu
- Bryan J. McEntireBMBryan J. McEntire
- Bhajanjit Sonny BalBBBhajanjit Sonny Bal
- Ryutaro AshidaRARyutaro Ashida
- Osam MazdaOMOsam Mazda
- Giuseppe PezzottiGPGiuseppe Pezzotti
Open Access
- 17 December 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (24) , 9039
Abstract
The performance, durability, and bio-integration of functional biomedical coatings can be enhanced by changing or improving their substrate properties. In this study, we applied silicon nitride powder-based laser claddings to various substrates and undertook an in vitro assessment of their osteoconductive and antibacterial properties. The substrates included common arthroplasty materials: polyethylene, titanium, zirconia-toughened alumina, and zirconia. Multiple analytical techniques were used to characterize the physical and chemical structure of the claddings after deposition. Partial decomposition of the silicon nitride powders occurred during the cladding process, resulting in nitrogen loss during intermetallic formation phases under some substrate and treatment conditions. The osteoconductive capabilities of various laser-cladded substrates were evaluated in a SaOS-2 osteosarcoma cell culture by measuring the amount of bone formation on the coated surface. Antibacterial testing was performed using Gram-positive Staphylococcus epidermidis at 24 and 48 h of incubation. Silicon nitride coating enhanced both osteoconductive and antibacterial properties.Keywords
This publication has 48 references indexed in Scilit:
- A systematic review of the causes of failure of Revision Total Hip ArthroplastyJournal of Orthopaedics, 2019
- Total hip arthroplasty: Survival and modes of failureEFORT Open Reviews, 2018
- Failure After Modern Total Knee Arthroplasty: A Prospective Study of 18,065 KneesThe Journal of Arthroplasty, 2018
- The biological response to orthopaedic implants for joint replacement: Part I: MetalsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2016
- Multifunctional coatings to simultaneously promote osseointegration and prevent infection of orthopaedic implantsBiomaterials, 2016
- Ceramics and ceramic coatings in orthopaedicsJournal of the European Ceramic Society, 2015
- Biomaterials in orthopaedicsJournal of The Royal Society Interface, 2008
- Bacteriostatic properties of biomatrices against common orthopaedic pathogensBiochemical and Biophysical Research Communications, 2004
- Biomedical applications of polymer-composite materials: a reviewComposites Science and Technology, 2001
- Processing of Bioglass Coatings by Excimer Laser AblationKey Engineering Materials, 2000