Femtosecond laser creation of donor cornea buttons for Descemet-stripping endothelial keratoplasty
Authors:
- Donald T. TanDTDonald T. Tan
- 1 November 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (11) , 1970-1975
Abstract
To evaluate the accuracy of the thickness and diameter of corneal disks obtained with the Femtec femtosecond laser (20/10 Perfect Vision) for Descemet-stripping endothelial keratoplasty (DSEK). Singapore National Eye Centre, Singapore. A femtosecond laser was used to create posterior stromal ablations at varying depths, producing donor lenticules 150 to 200 microm thick with diameters of 7.0 to 9.5 mm (n = 40). After stromal ablation, the central corneal thickness was measured by anterior segment optical coherence tomography and the diameters were measured using imaging software. The mean deviation from the attempted thickness was 15 +/- 14 microm. No correlation was found between the preoperative corneal thickness and the accuracy of the laser ablation (P = .91). No statistically significant differences were found in the accuracy of the laser ablation with multiple-pass nomograms (P = .15). The laser was accurate in producing circular diameters with an arc length between 7.0 mm and 9.5 mm (r2 = 0.935, P = .001). The femtosecond laser produced posterior stromal ablations that were accurate in depth of ablation and circularity.Keywords
This publication has 25 references indexed in Scilit:
- Femtosecond Laser-assisted Endothelial KeratoplastyCornea, 2008
- Descemet’s Stripping with Endothelial KeratoplastyOphthalmology, 2006
- Descemet-Stripping Automated Endothelial KeratoplastyCornea, 2006
- Reproducibility of Flap Thickness With IntraLase FS and Moria LSK-1 and M2 MicrokeratomesJournal of Refractive Surgery, 2006
- Femtosecond Laser Posterior Lamellar KeratoplastyCornea, 2005
- Femtosecond laser–assisted posterior lamellar keratoplastyInitial studies of surgical technique in eye bank eyesOphthalmology, 2005
- A Technique to Excise the Descemet Membrane From a Recipient Cornea (Descemetorhexis)Cornea, 2004
- Precision and accuracy of an artificial anterior chamber system in obtaining corneal lenticules for lamellar keratoplastyJournal of Cataract & Refractive Surgery, 2001
- Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1999
- Posterior lamellar keratoplasty for a case of pseudophakic bullous keratopathyAmerican Journal of Ophthalmology, 1999