High granularity tracker based on a Triple-GEM optically read by a CMOS-based camera

Authors:
  • MMMichela Marafini
    Michela Marafini
  • VPVincenzo Patera
    Vincenzo Patera
  • DPDavide Pinci
    Davide Pinci
  • ASAlessio Sarti
    Alessio Sarti
  • ASA. Sciubba
    A. Sciubba
  • ESEleuterio Spiriti
    Eleuterio Spiriti

Abstract
The detection of photons produced during the avalanche development in gas chambers has been well studied in the past. The great progresses achieved in last years in the performance of micro-pattern gas detectors on one side and of photo-sensors on the other provide the possibility of making high granularity and very sensitive particle trackers. In this paper, the results obtained with a triple-GEM structure read-out by a CMOS based sensor are described. The use of an He/CF$_4$ (60/40) gas mixture and a suitable study of the electric fields made possible to optimise GEM light yield. About 100 photons per primary electron were detected by the sensor resulting in a very good capability of tracking muons from cosmic rays.