Bispectral Index as a Predictor of Sedation Depth during Isoflurane or Midazolam Sedation in ICU Patients
Authors:
Open Access
- 1 June 2007
- journal article
- research article
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 35 (3) , 348-356
Abstract
Bispectral index (BIS) is used for monitoring anaesthetic depth with inhaled anaesthetic agents in the operating room but has not been evaluated as a monitor of sedation depth in the intensive care unit (ICU) setting with these agents. If BIS could predict sedation depth in ICU patients, patient disturbances could be reduced and oversedation avoided. Twenty ventilator-dependent ICU patients aged 27 to 80 years were randomised to sedation with isoflurane via the AnaConDa® or intravenous midazolam. BIS (A-2000 XP, version 3.12), electromyogram activity (EMG) and Signal Quality Index were measured continuously. Hourly clinical evaluation of sedation depth according to Bloomsbury Sedation Score (Bloomsbury) was performed. The median BIS value during a 10-minute interval prior to the clinical evaluation at the bedside was compared with Bloomsbury. Nurses performing the clinical sedation scoring were blinded to the BIS values. End-tidal isoflurane concentration was measured and compared with Bloomsbury. Correlation was poor between BIS and Bloomsbury in both groups (Spearman's rho 0.012 in the isoflurane group and -0.057 in the midazolam group). Strong correlation was found between BIS and EMG (Spearman's rho 0.74). Significant correlation was found between end-tidal isoflurane concentration and Bloomsbury (Spearman's rho 0.47). In conclusion, BIS XP does not reliably predict sedation depth as measured by clinical evaluation in non-paralysed ICU patients sedated with isoflurane or midazolam. EMG contributes significantly to BIS values in isoflurane or midazolam sedated, non-paralysed ICU patients. End-tidal isoflurane concentration appeared to be a better indicator of clinical sedation depth than BIS.Keywords
This publication has 28 references indexed in Scilit:
- Does the Use of Electroencephalographic Bispectral Index or Auditory Evoked Potential Index Monitoring Facilitate Recovery after Desflurane Anesthesia in the Ambulatory Setting?Anesthesiology, 2004
- Different benefit of bispectal index (BIS™) in desflurane and propofol anesthesiaActa Anaesthesiologica Scandinavica, 2003
- Is the bispectral index appropriate for monitoring the sedation level of mechanically ventilated surgical ICU patients?Intensive Care Medicine, 2002
- Reduced isoflurane consumption with bispectral index monitoringActa Anaesthesiologica Scandinavica, 2001
- Daily Interruption of Sedative Infusions in Critically Ill Patients Undergoing Mechanical VentilationNew England Journal of Medicine, 2000
- Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilationCritical Care Medicine, 1999
- Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation ScaleCritical Care Medicine, 1999
- Bispectral IndexCritical Care Medicine, 1999
- Bispectral Analysis Measures Sedation and Memory Effects of Propofol, Midazolam, Isoflurane, and Alfentanil in Healthy VolunteersAnesthesiology, 1997
- A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic EffectAnesthesia & Analgesia, 1997