Principles and applications of multienergy CT: Report of AAPM Task Group 291
Top Cited Papers
Open Access
- 25 March 2020
- journal article
- editorial
- Published by Wiley in Medical Physics
- Vol. 47 (7) , E881-E912
Abstract
In x‐ray computed tomography (CT), materials with different elemental compositions can have identical CT number values, depending on the mass density of each material and the energy of the detected x‐ray beam. Differentiating and classifying different tissue types and contrast agents can thus be extremely challenging. In multienergy CT, one or more additional attenuation measurements are obtained at a second, third or more energy. This allows the differentiation of at least two materials. Commercial dual‐energy CT systems (only two energy measurements) are now available either using sequential acquisitions of low‐ and high‐tube potential scans, fast tube‐potential switching, beam filtration combined with spiral scanning, dual‐source, or dual‐layer detector approaches. The use of energy‐resolving, photon‐counting detectors is now being evaluated on research systems. Irrespective of the technological approach to data acquisition, all commercial multienergy CT systems circa 2020 provide dual‐energy data. Material decomposition algorithms are then used to identify specific materials according to their effective atomic number and/or to quantitate mass density. These algorithms are applied to either projection or image data. Since 2006, a number of clinical applications have been developed for commercial release, including those that automatically (a) remove the calcium signal from bony anatomy and/or calcified plaque; (b) create iodine concentration maps from contrast‐enhanced CT data and/or quantify absolute iodine concentration; (c) create virtual non‐contrast‐enhanced images from contrast‐enhanced scans; (d) identify perfused blood volume in lung parenchyma or the myocardium; and (e) characterize materials according to their elemental compositions, which can allow in vivo differentiation between uric acid and non‐uric acid urinary stones or uric acid (gout) or non‐uric acid (calcium pyrophosphate) deposits in articulating joints and surrounding tissues. In this report, the underlying physical principles of multienergy CT are reviewed and each of the current technical approaches are described. In addition, current and evolving clinical applications are introduced. Finally, the impact of multienergy CT technology on patient radiation dose is summarized.Keywords
Funding Information
- Cancer Prevention and Research Institute of Texas
- GE Healthcare
This publication has 178 references indexed in Scilit:
- Vision 20/20: Single photon counting x‐ray detectors in medical imagingMedical Physics, 2013
- Gastric Cancer Staging with Dual Energy Spectral CT ImagingPLOS ONE, 2013
- Dual-Energy CT: General PrinciplesAmerican Journal of Roentgenology, 2012
- Dual-Energy CT Applications in Head and Neck ImagingAmerican Journal of Roentgenology, 2012
- Virtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image qualityMedical Physics, 2011
- Monoenergetic Imaging of Dual-energy CT Reduces Artifacts from Implanted Metal Orthopedic Devices in Patients with FacturesAcademic Radiology, 2011
- Incremental value of dual-energy CT to coronary CT angiography for the detection of significant coronary stenosis: comparison with quantitative coronary angiography and single photon emission computed tomographyThe International Journal of Cardiovascular Imaging, 2011
- Dual-Source Dual-Energy CT With Additional Tin Filtration: Dose and Image Quality Evaluation in Phantoms and In VivoAmerican Journal of Roentgenology, 2010
- Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissuesPhysics in Medicine & Biology, 2010
- Noninvasive Differentiation of Uric Acid versus Non–Uric Acid Kidney Stones Using Dual-Energy CTAcademic Radiology, 2007