Abstract
The occurrence of high frequency discharge bearing currents (also: "EDM-currents'") that can occur in machines of inverter-based drives systems depends strongly on the value of the capacitive voltage divider BVR (bearing voltage ratio) of the machine. This paper presents a straightforward approach to calculate the involved motor capacitances in order to predict the occurrence of discharge bearing currents in inverter-based drive system. The approach is based on the design parameters of the machine and does not involve additional measurements. It combines ease of application and satisfying accurateness and allows prediction of the risk of endangerment of an inverter-based drive system due to discharge bearing currents

This publication has 12 references indexed in Scilit: