A novel ISM‐SAM strategy, based on gas chromatography/mass spectrometry analysis, to compensate for matrix effects in the determination of pyruvic acid
- 4 January 2021
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (7) , e9042
Abstract
Rationale: The matrix effect is tricky in gas chromatography/mass spectrometry (GC/MS) analyses. Although several methods have been proposed to solve this problem, the results were unsatisfactory. Even fewer studies have assessed the performance of corrective methods. Hence, our study focused on assessing several common corrective methods, and then proposed a new strategy to correct for the matrix effect in GC/MS analyses. Methods: In GC/MS analyses, the internal standard method (ISM) was employed to overcome the matrix effect during the detection of pyruvic acid (PA) in serum samples from a healthy adult female. The accuracy of the ISM was evaluated by comparing it with the standard addition method (SAM). To employ the ISM‐SAM strategy, correction factors (CFs) were established by combining the ISM and the SAM based on different groups. The CFs were used to normalize data onto the results of subsequent analyses. Results: When using the ISM to detect levels of PA, a serious bias is observed, thereby affecting the conclusions reached. In contrast, more reliable data can be obtained after normalizing results by undertaking the ISM‐SAM strategy. The feasibility of this strategy was verified by comparing it with the results of the SAM alone. The ISM‐SAM strategy was successfully applied to quantify the PA levels in healthy people and nephrotic syndrome patients. Conclusions: Our results indicated that a false outcome was presented when only the ISM was used to adjust the data, and important information would be missed if the correction strategy was not carried out. Therefore, ISM‐SAM, as an available correction method, should be adapted to improve the reliability of research results.Keywords
This publication has 29 references indexed in Scilit:
- Standard addition flow method for potentiometric measurements at low concentration levels: Application to the determination of fluoride in food samplesTalanta, 2015
- Relationship between the matrix effect and the physicochemical properties of analytes in gas chromatographyAnalytical and Bioanalytical Chemistry, 2013
- Underestimation of Pyruvic Acid Concentrations by Fructose and Cysteine in 2,4‐Dinitrophenylhydrazine‐Mediated Onion Pungency TestJournal of Food Science, 2011
- Indirect determination of pyruvic acid by capillary electrophoresis with amperometric detectionJournal of Chromatography B, 2007
- Molecular Solvation in Water−Methanol and Water−Sorbitol Mixtures: The Roles of Preferential Hydration, Hydrophobicity, and the Equation of StateThe Journal of Physical Chemistry B, 2007
- Review of Univariate Standard Addition Calibration Procedures in Flow AnalysisCritical Reviews in Analytical Chemistry, 2006
- A modified protein precipitation procedure for efficient removal of albumin from serumElectrophoresis, 2005
- Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography–electrospray–tandem mass spectrometryClinical Biochemistry, 2005
- Evaluation of two-dimensional gas chromatography–time-of-flight mass spectrometry for the determination of multiple pesticide residues in fruitJournal of Chromatography A, 2003
- Dependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solutionAnalytical Chemistry, 1993