A surface-modified sperm sorting device with long-term stability
- 1 June 2006
- journal article
- research article
- Published by Springer Nature in Biomedical Microdevices
- Vol. 8 (2) , 99-107
Abstract
Microfluidic devices fabricated from poly (dime- thylsiloxane) (PDMS) offer the ability to improve our biological and medical capabilities. Although PDMS offers a range of intriguing benefits for biomedical applications, the intrinsically hydrophobic nature of PDMS may impede with the tremendous potential of these devices. Here, we describe a PDMS-based sperm sorting device, which has been surface-modified via graft-co-polymerization of poly(ethylene glycol) methyl ether methacrylate to create a moderately hydrophilic and non-fouling surface. This process involves the exposure of PDMS to UV/ozone, which activates the PDMS surface to bond to the substrate and, at the same time, initiates the graft-co-polymerization from the PDMS surface. In this study, we confirmed long-term stability of surface-modified PDMS for up to 56 days based on Fourier transformation infrared spectroscopy (FTIR), contact angle measurements, and protein adsorption studies. Moreover, the applicability of our method to PDMS-based sperm sorting devices was demonstrated by successfully sorting human sperm.Keywords
This publication has 16 references indexed in Scilit:
- Hydrophobic recovery of UV/ozone treated poly(dimethylsiloxane): adhesion studies by contact mechanics and mechanism of surface modificationApplied Surface Science, 2005
- Photochemical Modification of Cross-Linked Poly(dimethylsiloxane) by Irradiation at 172 nmMacromolecules, 2004
- Tailoring the Surface Properties of Poly(dimethylsiloxane) Microfluidic DevicesLangmuir, 2004
- UV/ozone modification of poly(dimethylsiloxane) microfluidic channelsSensors and Actuators B: Chemical, 2004
- Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studiesElectrophoresis, 2003
- Surface modification in microchip electrophoresisElectrophoresis, 2003
- Rethinking gamete/embryo isolation and culture with microfluidicsHuman Reproduction Update, 2003
- Reactive Polymer Coatings: A First Step toward Surface Engineering of Microfluidic DevicesAnalytical Chemistry, 2003
- Plasma-induced graft polymerization of poly(ethylene glycol) methyl ether methacrylate on poly(tetrafluoroethylene) films for reduction in protein adsorptionSurface and Coatings Technology, 2002
- Preparation and Characterization of Comb-like PEO Gradient SurfacesJournal of Colloid and Interface Science, 1996