Detection of Induction Motor Coupling Unbalanced and Misalignment via Advanced Transient Current Signature Analysis
Authors:
- Jose Antonino-DaviuJose Antonino-Daviu
- Peter PopalenyPPPeter Popaleny
- 1 September 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2359-2364
Abstract
In industry, vibration analysis is often employed for the detection of mechanical failures in rotating electrical machinery. However, there are some applications in which the installation of vibration sensors is not feasible or the access to the motor is limited. In these cases, the use of alternative techniques, such as the analysis of motor currents may bring significant advantages. In this context, over these recent years, advanced methods based on the analysis of transient motor currents have proven to be very effective for the detection of certain faults, avoiding the drawbacks of classical current analysis methods. This paper proposes the analysis of the starting current to detect different types of mechanical faults in induction motors. Motor misalignment caused by loosened bolts and soft foot as well as coupling unbalance are considered in the work. The results show that the advanced analysis of starting currents brings very useful information to detect the presence of these anomalies, becoming an excellent informational source for the diagnosis of these types of failures.Keywords
This publication has 17 references indexed in Scilit:
- Combination of Noninvasive Approaches for General Assessment of Induction MotorsIEEE Transactions on Industry Applications, 2014
- Advanced Induction Motor Rotor Fault Diagnosis Via Continuous and Discrete Time–Frequency ToolsIEEE Transactions on Industrial Electronics, 2014
- Advanced rotor assessment of motors operating under variable load conditions in mining facilities2014
- Fault detection in induction motors and the impact on the kinematic chain through thermographic analysisElectric Power Systems Research, 2014
- Reliable Detection of Induction Motor Rotor Faults Under the Rotor Axial Air Duct InfluenceIEEE Transactions on Industry Applications, 2014
- Detection of combined faults in induction machines with stator parallel branches through the DWT of the startup currentMechanical Systems and Signal Processing, 2009
- DWT analysis of numerical and experimental data for the diagnosis of dynamic eccentricities in induction motorsMechanical Systems and Signal Processing, 2007
- Notice of Violation of IEEE Publication Principles: Using Current Signature Analysis Technology to Reliably Detect Cage Winding Defects in Squirrel-Cage Induction MotorsIEEE Transactions on Industry Applications, 2007
- A frequency-domain detection of stator winding faults in induction machines using an external flux sensorIEEE Transactions on Industry Applications, 2003
- Vibration and current monitoring for detecting airgap eccentricity in large induction motorsIEE Proceedings B Electric Power Applications, 1986