A prospective case control comparison of the ZeroGravity system versus a standard lead apron as radiation protection strategy in neuroendovascular procedures
Authors:
- 21 October 2015
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 8 (10) , 1052-1055
Abstract
Background and purpose We aimed to compare the performance of the ZeroGravity (ZG) system (radiation protection system composed by a suspended lead suit) against the use of standard protection (lead apron (LA), thyroid shield, lead eyeglasses, table skirts, and ceiling suspended shield) in neuroangiography procedures. Materials and methods Radiation exposure data were prospectively collected in consecutive neuroendovascular procedures between December 2014 and February 2015. Operator No 1 was assigned to the use of an LA (plus lead glasses, thyroid shield, and a 1 mm hanging shield at the groin) while operator No 2 utilized the ZG system. Dosimeters were used to measure peak skin dose for the head, thyroid, and left foot. Results The two operators performed a total of 122 procedures during the study period. The ZG operator was more commonly the primary operator compared with the LA operator (85% vs 71%; p=0.04). The mean anterior-posterior (AP), lateral, and cumulative dose area product (DAP) radiation exposure as well as the mean fluoroscopy time were not statistically different between the operators’ cases. The peak skin dose to the head of the operator with LA was 2.1 times higher (3380 vs 1600 μSv), while the thyroid was 13.9 (4460 vs 320 μSv), the mediastinum infinitely (520 vs 0 μSv), and the foot 3.3 times higher (4870 vs 1470 μSv) compared with the ZG operator, leading to an overall accumulated dose 4 times higher. The ratio of cumulative operator received dose/total cumulative DAP was 2.5 higher on the LA operator. Conclusions The ZG radiation protection system leads to substantially lower radiation exposure to the operator in neurointerventional procedures. However, substantial exposure may still occur at the level of the lens and thyroid to justify additional protection.Keywords
This publication has 9 references indexed in Scilit:
- Abstract No. 312: Comparison of operator eye exposures when working from femoral region, side, or head of patientJournal of Vascular and Interventional Radiology, 2012
- Comparison of a Suspended Radiation Protection System versus Standard Lead Apron for Radiation Exposure of a Simulated InterventionalistJournal of Vascular and Interventional Radiology, 2011
- Comparing Strategies for Operator Eye Protection in the Interventional Radiology SuiteJournal of Vascular and Interventional Radiology, 2010
- Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplastyBritish Journal of Radiology, 2010
- Protective aprons in imaging departments: manufacturer stated lead equivalence values require validationEuropean Radiology, 2005
- Risk of whole body radiation exposure and protective measures in fluoroscopically guided interventional techniques: a prospective evaluationBMC Anesthesiology, 2003
- Patient and occupational dose in neurointerventional proceduresNeuroradiology, 2002
- Prevalence of Spinal Disc Disease Among Interventional CardiologistsThe American Journal of Cardiology, 1997
- The Case for Radioprotective Eyewear/FacewearInvestigative Radiology, 1987