Design of a Hydraulic Prosthetic Knee With Control Moment for Adjustable Stance-Phase Knee Flexion
Open Access
- 19 November 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 4687-4696
Abstract
Lower-limb amputees worldwide have been increasing continuously in recent years. Hydraulic knees are suitable for active transfemoral amputees in developing countries due to their adaptability to various walking speeds and greater accessibility compared to high-end prosthetics. However, most hydraulic prosthetic knees operate via ground reaction force control, which exhibits a double-peak characteristic, causing slight flexion during the early stance phase, leading to unnatural and asymmetrical gait patterns for amputees. This study proposes a novel technique that expands the concept of the two-axis for application in a hydraulic prosthetic knee, utilizing the control moment to achieve stance-phase control (CMSPC knee). The control moment exhibits only one positive peak during the stance phase, allowing for adjustment of suitable stance-phase knee flexion by varying the spring stiffness. The single-subject walking experiment was conducted in the gait laboratory with one transfemoral amputee to evaluate the conceptual design. The subject walked on a treadmill at a constant velocity of 0.9 m/s, a self-selected walking speed, for 30 seconds, repeated four times for each spring stiffness. The results showed that the CMSPC knee can adjust the maximum stance-phase knee flexion from approximately 4.15° to 13.89°, which is roughly the same range observed in non-disabled individuals. Finally, most gait symmetry in temporal variables was significantly improved, with comparable results between the best condition, at a spring stiffness of 12.2 N/mm, and the condition without a spring (Mann-Whitney, p < 0.05). The condition without a spring is represented by hydraulic knees that offer slight stance-phase knee flexion.Keywords
Funding Information
- Second Century Fund (C2F), Chulalongkorn University
This publication has 38 references indexed in Scilit:
- Development of four-bar polycentric knee joint with stance-phase knee flexionScientific Reports, 2023
- A kinematic and kinetic dataset of 18 above-knee amputees walking at various speedsScientific Data, 2020
- Temporal Spatial and Metabolic Measures of Walking in Highly Functional Individuals With Lower Limb AmputationsArchives of Physical Medicine and Rehabilitation, 2017
- Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic kneesClinical Biomechanics, 2012
- A multiple-task gait analysis approach: Kinematic, kinetic and EMG reference data for healthy young and adult subjectsGait & Posture, 2011
- Biomechanics and Motor Control of Human Movement2009
- Cost-Effectiveness of C-Leg Compared With Non–Microprocessor-Controlled Knees: A Modeling ApproachArchives of Physical Medicine and Rehabilitation, 2008
- Dynamic analysis of above-knee amputee gaitClinical Biomechanics, 2007
- Evaluation of Function, Performance, and Preference as Transfemoral Amputees Transition From Mechanical to Microprocessor Control of the Prosthetic KneeArchives of Physical Medicine and Rehabilitation, 2007
- The prevalence of knee pain and symptomatic knee osteoarthritis among veteran traumatic amputees and nonamputeesArchives of Physical Medicine and Rehabilitation, 2005