Measurement of Low Breath-Alcohol Concentrations: Laboratory Studies and Field Experience
Authors:
Open Access
- 1 October 1999
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 23 (6) , 386-395
Abstract
Recent federal rules and traffic law changes impose breath-alcohol thresholds of 0.02 and 0.04 g/210 L upon some classes of motor vehicle operators, such as juveniles and commercial vehicle operators. In federally regulated alcohol testing in the workplace, removal of covered workers from safety-sensitive duties, and other adverse actions, also occur at breath-alcohol concentrations (BrACs) of 0.02 and 0.04 g/210 L. We therefore studied performance of vapor-alcohol and breath-alcohol measurement at low alcohol concentrations in the laboratory and in the field, with current-generation evidential analyzers. We report here chiefly our field experience with evidential breath-alcohol testing of drinking drivers on paired breath samples using 62 Intoxilyzer 5000-D analyzers, for BrACs of 0–0.059 g/210 L. The data from 62 law enforcement breath-alcohol testing sites were collected and pooled, with BrACs recorded to three decimal places, and otherwise carried out under the standard Oklahoma evidential breath-alcohol testing protocol. For 2105 pooled simulator control tests at 0.06–0.13 g/210 L the mean − SD of the differences between target and result were −0.001 ± 0.0035 g/210 L and 0.003 ± 0.0023 g/210 L for signed and absolute differences, respectively (spans −0.016–0.010, 0.000–0.016). For 2078 paired duplicate breath-alcohol measurements with the Intoxilyzer 5000-D, the mean − SD difference (BrAC 1 - BrAC 2) were 0.002 ± 0.0026 (span 0–0.020 g/210 L). Variability of breath-alcohol measurements was related inversely to the alcohol concentration. Ninety-nine percent prediction limits for paired BrAC measurements correspond to a 0.020 g/210 L maximum absolute difference, meeting the NSC/CAOD recommendation that paired breath-alcohol analysis results within 0.02 g/210 L shall be deemed to be in acceptable agreement. We conclude that the field system for breath-alcohol analysis studied by us can and does perform reliably and accurately at low BrACs.Keywords
This publication has 6 references indexed in Scilit:
- Vapor-Alcohol Control Tests with Compressed Ethanol-Gas Mixtures: Scientific Basis and Actual PerformanceJournal of Analytical Toxicology, 1996
- Repeatability of replicate breath alcohol measurements collected in short time intervalsScience & Justice, 1995
- Quality Assurance in Breath-Alcohol Analysis*Journal of Analytical Toxicology, 1994
- Evaluation of Commercial Breath-Alcohol Simulators: Further StudiesJournal of Analytical Toxicology, 1991
- Statistical Evaluation of Truncated Breath-Alcohol Test MeasurementsJournal of Forensic Sciences, 1988
- The rapid estimation and control of precision by duplicate determinationsThe Analyst, 1973