CBCT Evaluation of Cortical Bone Thickness for Orthodontic Mini-Screw
Authors:
- Enkh-Orchlon BatbayarEBEnkh-Orchlon Batbayar
- Ganjargal GanburgedGGGanjargal Ganburged
Open Access
- 3 October 2021
- journal article
- research article
- Published by Mongolian National University of Medical Sciences in Central Asian Journal of Medical Sciences
- Vol. 7 (3) , 277-284
Abstract
Objectives: This study aimed to assess mandibular and maxillary cortical bone thickness using a cone beam computer tomogram (CBCT) image to determine the safe zone to insert mini-screws. Methods: In this three factorial design study, we included 100 subjects divided into age group 1 (age 16-44 yrs.) and age group 2 (age 26-42 yrs.) that had taken a CBCT in the Department of Orthodontics, School of Dentistry, Mongolian National University Medical Sciences (MNUMS) from 2014-2021 We used CBCT images in the 100 subjects that were obtained with DENTRI (HDXWILL, Seoul, Korea) using OnDemand3D software for linear measurements. Results: The maxillary cortical bone thickness was heavier in the male gender at the premolar region level of 5 mm in age group I. Maximum maxillary cortical bone thickness as measured 7 mm from the Cemento-Enamel Junction (CEJ) between the 1st premolar and 2nd premolar was 0.99 mm, and the mandibular cortical bone thickness as measured 7 mm from the CEJ between the 1st molar and 2nd molar was 2.11 mm. Conclusion: This suggests that the maxillar and mandibular molar teeth cortical bone thickness on the buccal side of 7mm from the CEJ is considered to be the safest position to implant mini screws in cortical bone.Keywords
This publication has 21 references indexed in Scilit:
- Gender and growth variation in palatal bone thickness and density for mini-implant placementProgress in Orthodontics, 2018
- Maxillary Cortical Bone Thickness in a South-Eastern Anatolian Population: A Cone-Beam Computed Tomography StudyMedical Science Monitor, 2017
- Guidelines for clinical use of CBCT: a reviewDentomaxillofacial Radiology, 2015
- Evaluation of orthodontic mini-implant placement: a CBCT studyProgress in Orthodontics, 2014
- Clinical Effectiveness of Orthodontic Miniscrew Implants: a Meta-analysisJournal of Dental Research, 2011
- Cortical bone thickness at common miniscrew implant placement sitesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Buccal cortical bone thickness for mini-implant placementAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Change in maximum occlusal force in association with maxillofacial growthOrthodontics & Craniofacial Research, 2007
- Managing complex orthodontic problems: the use of implants for anchorageSeminars in Orthodontics, 1996
- A study of maximum bite force during growth and development.1996