Ratiometric fluorescent aptasensor for convenient detection of ochratoxin A in beer and orange juice
- 31 August 2023
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (20) , 5172-5177
Abstract
Based on the principle of fluorescence resonance energy transfer (FRET), a simple ratiometric fluorescent aptasensor for convenient detection of ochratoxin A (OTA), a Group IIB carcinogen secreted by some fungi, was established. Initially, the anti-OTA aptamer with a quadruplex structure was flanked with FAM and BHQ1, and its partially complementary DNA (cDNA) was tagged with Cy3. In the absence of OTA, this aptamer hybridized with the cDNA strand forming a DNA duplex structure, in which BHQ1 was adjacent to Cy3 and distant from FAM. Due to the FRET principle, the fluorescence intensity emitted by Cy3 (FCy3) was quenched by BHQ1, and the fluorescence intensity emitted by FAM (FFAM) recovered. In the presence of OTA, the prepared aptamer preferred to bind with OTA instead of cDNA, forming an aptamer–OTA complex structure in which BHQ1 was adjacent to FAM and distant from Cy3. As a result, FFAM was quenched and FCy3 was restored. OTA can be accurately detected via the determination of the FCy3/FFAM ratio value. Under optimal conditions, this ratiometric fluorescent aptasensor offers excellent OTA detection in the range of 0.6 nmol L−1–5 μmol L−1, with a limit of detection (LOD) of 0.3 nmol L−1. This ratiometric aptasensor showed the advantages of easy operation, accuracy and sensitive analysis. Good specificity of this aptasensor was demonstrated. This ratiometric aptasensor could be used for the detection of OTA in real samples, e.g. beer and orange juice, showing its promising application potential.Keywords
Funding Information
- Natural Science Foundation of Shandong Province (ZR2021QB206)
This publication has 36 references indexed in Scilit:
- Structure-guided post-SELEX optimization of an ochratoxin A aptamerNucleic Acids Research, 2019
- Electrochemical Aptamer-Based Sensors for Rapid Point-of-Use Monitoring of the Mycotoxin Ochratoxin A Directly in a Food StreamMolecules, 2018
- Mycotoxins as human carcinogens—the IARC Monographs classificationMycotoxin Research, 2016
- Ochratoxin A: 50 Years of ResearchToxins, 2016
- Colorimetric aptasensing of ochratoxin A using Au@Fe3O4 nanoparticles as signal indicator and magnetic separatorBiosensors and Bioelectronics, 2016
- A FRET-based ratiometric fluorescent aptasensor for rapid and onsite visual detection of ochratoxin AThe Analyst, 2015
- Aptamers as a replacement for antibodies in enzyme-linked immunosorbent assayBiosensors and Bioelectronics, 2015
- Ochratoxin A and Human Health Risk: A Review of the EvidenceCritical Reviews in Food Science and Nutrition, 2013
- Fabricated aptamer-based electrochemical “signal-off” sensor of ochratoxin ABiosensors and Bioelectronics, 2010
- Determination of Ochratoxin A with a DNA AptamerJournal of Agricultural and Food Chemistry, 2008