Improvement of abundance sensitivity in a quadrupole-based ICP-MS instrument with a hexapole collision cell
- 3 July 2002
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1202-1206
Abstract
High isotopic abundance sensitivity is desirable for the measurement of low-abundance isotopes in the presence of neighboring high-abundance isotopes. This is of interest when analyzing ultra low concentrations of trace elements or isotopes in the presence of elements or isotopes with much higher concentrations (e.g., radionuclides included in a matrix of stable isotopes). In this study, a quadrupole-based inductively coupled plasma mass spectrometer with a hexapole collision cell (ICP-CC-QMS), Platform ICP (Micromass UK), was used to study the improvement of abundance sensitivity using uranium and lutetium as examples. The median kinetic energy of 238U+ ions was about 1.2 eV and 0.9 eV when helium was introduced as a collision gas at flow rates of 5 ml min−1 and 10 ml min−1, respectively. In the latter case, the proportion of ions with relatively high energy decreased significantly, which improved both the transmission of ions through the hexapole collision cell and mass selection by the quadrupole mass spectrometer. When introducing helium into the collision cell a reduction in peak tail of high-abundance isotopes by up to three orders of magnitude, depending on the mass analyzed, was observed. The abundance sensitivity for 236U/238U isotope ratio was improved from 2.3 × 10−5 to 6.3 × 10−8. Abundance sensitivities as low as 3.5 × 10−8, 6.6 × 10−8 and 2.0 × 10−8 were achieved at masses m − 2.5 u, m − 1.5 u and m + 2.5 u (m = 174.94 u for 175Lu), respectively. Reducing the kinetic energy also improved the mass resolution by about 10%. However, increasing the mass resolution of the quadrupole instrument had a significantly lower influence on abundance sensitivity than reducing the ion energy by collision with helium atoms. The present study of the effect of the pressurized ion guide on abundance sensitivity was limited to some extent because of the relatively high background count rate of the Daly-type ion detector in the ICP-CC-QMS system. An ion detector possessing a low background would be desirable for further studies. Improved abundance sensitivity can be useful in analyzing long-lived radionuclides like 236U and 129I in the presence of high-abundance stable isotopes like 238U and 127I.Keywords
This publication has 18 references indexed in Scilit:
- Inappropriate tail corrections can cause large inaccuracy in isotope ratio determination by MC-ICP-MSJournal of Analytical Atomic Spectrometry, 2001
- Isotope ratio measurements of spent reactor uranium in environmental samples by using inductively coupled plasma mass spectrometryInternational Journal of Mass Spectrometry, 2000
- Kinetic energy dependence of ion–molecule reactions: guided ion beams and threshold measurementsInternational Journal of Mass Spectrometry, 2000
- Peak shape for a quadrupole mass spectrometer: comparison of computer simulation and experimentInternational Journal of Mass Spectrometry, 2000
- Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cellJournal of Analytical Atomic Spectrometry, 2000
- Inorganic mass spectrometric methods for trace, ultratrace, isotope, and surface analysisInternational Journal of Mass Spectrometry, 2000
- Isotopic “fingerprints” for natural uranium ore samplesInternational Journal of Mass Spectrometry, 1999
- Properties and performance of a quadrupole mass filter used for resonance ionization mass spectrometryInternational Journal of Mass Spectrometry, 1998
- Precision and accuracy in isotope ratio measurements by plasma source mass spectrometryJournal of Analytical Atomic Spectrometry, 1998
- Effect of charge exchange reactions on the motion of ions in three-dimensional quadrupole electric fieldsInternational Journal of Mass Spectrometry and Ion Physics, 1976