Push–Pull Perfusion Sampling with Segmented Flow for High Temporal and Spatial Resolution in Vivo Chemical Monitoring
- 23 May 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (13) , 5207-5213
Abstract
Low-flow push–pull perfusion is a sampling method that yields better spatial resolution than competitive methods like microdialysis. Because of the low flow rates used (50 nL/min), it is challenging to use this technique at high temporal resolution which requires methods of collecting, manipulating, and analyzing nanoliter samples. High temporal resolution also requires control of Taylor dispersion during sampling. To meet these challenges, push–pull perfusion was coupled with segmented flow to achieve in vivo sampling at 7 s temporal resolution at 50 nL/min flow rates. By further miniaturizing the probe inlet, sampling with 200 ms resolution at 30 nL/min (pull only) was demonstrated in vitro. Using this method, l-glutamate was monitored in the striatum of anesthetized rats. Up to 500 samples of 6 nL each were collected at 7 s intervals, segmented by an immiscible oil and stored in a capillary tube. The samples were assayed offline for l-glutamate at a rate of 15 samples/min by pumping them into a reagent addition tee fabricated from Teflon where reagents were added for a fluorescent enzyme assay. Fluorescence of the resulting plugs was monitored downstream. Microinjection of 70 mM potassium in physiological buffered saline evoked l-glutamate concentration transients that had an average maxima of 4.5 ± 1.1 μM (n = 6 animals, 3–4 injections each) and rise times of 22 ± 2 s. These results demonstrate that low-flow push–pull perfusion with segmented flow can be used for high temporal resolution chemical monitoring and in complex biological environments.Keywords
This publication has 38 references indexed in Scilit:
- Monitoring Rapid Chemical Communication in the BrainChemical Reviews, 2008
- In Vivo Measurements of Neurotransmitters by Microdialysis SamplingAnalytical Chemistry, 2006
- Transient changes in nucleus accumbens amino acid concentrations correlate with individual responsivity to the predator fox odor 2,5‐dihydro‐2,4,5‐trimethylthiazolineJournal of Neurochemistry, 2005
- High temporal resolution for in vivo monitoring of neurotransmitters in awake epileptic rats using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detectionJournal of Neuroscience Methods, 2004
- On-Line Coupling of Microdialysis Sampling with Microchip-Based Capillary ElectrophoresisAnalytical Chemistry, 2004
- Demonstration of low flow push–pull perfusionJournal of Neuroscience Methods, 2002
- In vivo microdialysis as a tool for monitoring pharmacokineticsTrAC Trends in Analytical Chemistry, 2000
- Simultaneous comparison of cerebral dialysis and push–pull perfusion in the brain of rats: a critical reviewNeuroscience & Biobehavioral Reviews, 1998
- High Temporal Resolution Monitoring of Glutamate and Aspartate in Vivo Using Microdialysis On-Line with Capillary Electrophoresis with Laser-Induced Fluorescence DetectionAnalytical Chemistry, 1997
- Glutamate measured by 6-s resolution brain microdialysis: capillary electrophoretic and laser-induced fluorescence detection applicationJournal of Chromatography B: Biomedical Sciences and Applications, 1997