The Decontamination Effect of an Oscillating Chitosan Brush Compared With an Ultrasonic PEEK‐Tip: An In Vitro Study Using a Dynamic Biofilm Model
- 18 October 2024
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 36 (1) , 73-81
Abstract
Objectives: This study aimed to assess the effect of an oscillating chitosan brush (OCB) compared with an ultrasonic device with PEEK tip (US‐PEEK) for mechanical implant surface decontamination using an in vitro model combining 3D models and a validated dynamic multispecies biofilm.Materials and Methods: A multispecies biofilm using six bacterial strains (Streptococcus oralis, Veillonella parvula, Actinomyces naeslundii, Fusobacterium nucleatum, Porphyromonas gingivalis, and Aggregatibacter actinomycetemcomitans) was seeded on dental implants with machined and sandblasted, large‐grit and acid‐etched (SLA) surfaces. These were installed in 3D models depicting peri‐implant defect. Mechanical decontamination was performed for 120 s using either an OCB or a US‐PEEK. A negative control group received no treatment. Scanning electron microscopy (SEM) was used to evaluate the bacterial composition and quantitative PCR (qPCR) analyzed the number of each bacterial species [colony‐forming units per milliliter (CFU/mL)].Results: Well‐structured biofilms with a dense microbial distribution were observed on the negative control implants after 72 h. qPCR following mechanical decontamination showed a scarce bacterial reduction in the OCB group. The US‐PEEK group exhibited a significant decrease in bacterial species compared to both OCB and control groups (p < 0.05). A biofilm removal effect was also observed in the OCB group for the machined implant surfaces.Conclusion: In vitro assessment using an anatomical 3D model showed that mechanical decontamination effectively reduced biofilm. The US‐PEEK group demonstrated biofilm reduction on the SLA surface, while the OCB group showed a reduction on the machined implant surface. Additionally, the US‐PEEK group demonstrated greater efficacy in reducing bacterial numbers.Keywords
This publication has 43 references indexed in Scilit:
- Anatomical three‐dimensional model with peri‐implant defect for in vitro assessment of dental implant decontaminationClinical and Experimental Dental Research, 2024
- Mechanical removal of biofilm on titanium discs: An in vitro studyJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2021
- Cleaning potential of different air abrasive powders and their impact on implant surface roughnessClinical Implant Dentistry and Related Research, 2019
- Morphology and severity of peri‐implantitis bone defectsClinical Implant Dentistry and Related Research, 2019
- Nonsurgical Treatment of PeriimplantitisImplant Dentistry, 2019
- Chitosan as a bioactive polymer: Processing, properties and applicationsInternational Journal of Biological Macromolecules, 2017
- Response to antiseptic agents of periodontal pathogens in in vitro biofilms on titanium and zirconium surfacesDental Materials, 2017
- Scaling of titanium implants entrains inflammation-induced osteolysisScientific Reports, 2017
- Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic reviewInternational Journal of Oral and Maxillofacial Surgery, 2015
- An in vitro biofilm model associated to dental implants: Structural and quantitative analysis of in vitro biofilm formation on different dental implant surfacesDental Materials, 2014